BACKGROUND Recent infection testing algorithms (RITAs) are used in public health surveillance to estimate the incidence of recently acquired HIV-1 infection. OBJECTIVES Our aims were (i) to evaluate the precision of the VITROS® Anti-HIV 1+2 automated antibody avidity assay for qualitative detection of antibodies to HIV 1+2 virus; (ii) to validate the accuracy of an automated guanidine-based antibody avidity assay to discriminate between recent and long standing infections using the VITROS 3600 platform; (iii) to compare this method with BED-CEIA assay; and (iv) to evaluate the occurrence of false recent misclassifications by the VITROS antibody avidity assay in patients with a CD4 count <200 cells/μL and in patients on combination antiretroviral therapy (cART). RESULTS The VITROS® antibody avidity assay is highly reproducible. The ROC curve analysis of the accuracy of this assay, optimized for sensitivity and specificity, had an AI cut off of ≤0.51, with sensitivity and specificity values of 86.67% (95% CI: 72.51-94.46) and 86.24% (95% CI: 78.00-91.84), respectively. The agreement between VITROS antibody avidity and BED-CEIA assays was good. Misclassifications of long standing infections as recent infection occurred in 8.2% of patients with CD4 <200 cell/μL and 8.7% in patients on combination antiretroviral therapy. CONCLUSIONS The VITROS antibody avidity assay is a reliable serological method to detect recent HIV-1 infections and it could be incorporated into a RITA to estimate HIV incidence.
منابع مشابه
Comparision between Avidity Test and Detuned Elisa Test in Detecting the Recent and Established Hiv-1 Infection
Identifying patients with early human immunodeficiency virus infection is an important public health goal. Those individuals who have acquired human immunodeficiency virus infection recently have high viral loads both in their blood and genital secretions, thus facilitating transmission. Identifying and intervening these individuals early in the course of their disease, helps to reduce onward t...
متن کاملQuantification Analysis of Dot Blot Assays for Human Immunodeficiency Virus Type 1 and 2 Antibodies
Objective Dot Blot (DB) assay provides highly specific results, but usually not reliable for quantification of antibody production. The need for a more objective DB assay to provide a better definition of the immune status, against HIV antigens, promoted this study to be done to develop a quantitative DB assay. Material and Methods Dot blot (DB) strips for antibodies directed to human immuno...
متن کاملModification of AxSYM Human Immunodeficiency Virus Assay to Identify Recent Human Immunodeficiency Virus Infections in Korean Human Immunodeficiency Virus-Positive Individuals
OBJECTIVES To estimate human immunodeficiency virus (HIV) incidence using HIV avidity assays in Korea, we established a serological testing method to differentiate recent HIV infections from long-standing ones. METHODS We adopted two incidence assays, the BED HIV-1 incidence test (Calypte Biomedical) and an HIV avidity assay (using Abbott AxSYM HIV Antigen/Antibody Combo), and performed them ...
متن کاملPerformance Evaluation of the VIDAS® Measles IgG Assay and Its Diagnostic Value for Measuring IgG Antibody Avidity in Measles Virus Infection
The objective of this study is primarily to compare the performance of the VIDAS(®) Measles immunoglobulin (Ig)G assay to that of two other serological assays using an immunoassay technique, Enzygnost(®) Anti-measles Virus/IgG (Siemens) and Measles IgG CAPTURE EIA(®) (Microimmune). The sensitivity and the agreement of the VIDAS(®) Measles IgG assay compared to the Enzygnost(®) Anti-measles Viru...
متن کاملDiagnosis of human immunodeficiency virus infection using an immunoglobulin E-based assay.
Immunoglobulin assays that are sensitive and specific for detecting human immunodeficiency virus type 1 (HIV-1) infection are especially important in developing countries where PCR and viral culture may not be readily available. Immunoglobulin E (IgE), which is elevated in HIV-1 infection, is the only antibody that does not cross the placenta, making it potentially valuable for viral detection ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Enfermedades infecciosas y microbiologia clinica
دوره 33 4 شماره
صفحات -
تاریخ انتشار 2015