Randomized study comparing the efficacy of a self-retaining bicanaliculus intubation stent with Crawford intubation in patients with canalicular obstruction

نویسندگان

  • Syed Ziaeddin Tabatabaie
  • Mohammad Taher Rajabi
  • Mohammad Bagher Rajabi
  • Bahram Eshraghi
چکیده

BACKGROUND The purpose of this study was to compare the efficacy of self-retaining stent (SRS) bicanalicular intubation with bicanalicular silicone (Crawford) intubation in patients with canalicular and punctal obstruction. METHODS In this prospective, randomized clinical trial, 38 patients with canalicular or punctal obstruction (25 partial, 13 complete) and epiphora were randomized into two groups. Twenty-one patients (14 with partial and seven with complete obstruction) underwent SRS intubation and 17 patients underwent bicanalicular silicon intubation in a randomized fashion. RESULTS After a mean follow-up of 6 months following tube removal, 16 (76%, 12 partial, four complete) of the 21 eyes in the SRS intubation group and 13 (76%, 10 partial, three complete) in the bicanalicular silicon intubation group had a successful outcome and remained symptom-free. For partial obstructions, the success rate was 85% and 90% for the SRS and bicanalicular silicon intubation groups, respectively. The corresponding values for complete obstruction were 63% and 50% for the SRS and bicanalicular silicon intubation groups, respectively. CONCLUSION SRS could effectively substitute for a more extensive procedure such as bicanalicular silicon intubation in patients with canalicular obstruction, particularly those with partial obstruction. The newly developed SRS intubation procedure has the advantages of simple, easy implementation and extubation, low cost, and a lower rate of trauma when compared with bicanalicular silicon intubation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgical Results of Endoscopic Dacryocystorhinostomy and Lacrimal Trephination in Distal or Common Canalicular Obstruction

OBJECTIVES To evaluate the surgical outcomes of endoscopic dacryocystorhinostomy followed by canalicular trephination and silicone stenting in patients with distal or common canalicular obstructions. METHODS The medical records of 29 patients (31 eyes) from January 2001 to December 2009 who underwent endoscopic dacryocystorhinostomy followed by canalicular trephination and silicone tube inser...

متن کامل

Comparing the Effect of Dexamethasone before and after Tracheal Intubation on Sore Throat after Tympanoplasty Surgery: A Randomized Controlled trial

Introduction: Presence of a sore throat after surgery is a common side effect of general anesthesia with intratracheal intubation and can cause discomfort for the patient and prolong the recovery process. In this study we compared the effect of dexamethasone before and after intubation on the incidence of sore throat after tympanoplasty surgery.   Materials and Methods: In a double-blind, rando...

متن کامل

A modified technique of retrograde intubation dacryocystorhinostomy for proximal canalicular obstruction

PURPOSE To describe a modification of the retrograde intubation dacryocystorhinostomy (DCR) in patients with proximal canalicular obstruction. MATERIALS AND METHODS Interventional case report of a 43-year-old female with a nine-month history of left epiphora following a road traffic accident involving the proximal lower canaliculus. An external DCR approach was performed. Following the creati...

متن کامل

Self-Securing Monocanalicular Stent for Treatment of Nasolacrimal Duct Obstruction

Background: To report the clinical experience and analysis of our results with Ritleng intubation system in patients with congenital and acquired nasolacrimal duct obstruction. Methods: Silicone intubation with the Ritleng lacrimal system was performed in 17 patients (20 eyes) from March 2001 to March 2003 to relieve nasolacrimal duct obstruction following the failure of nasolacrimal duct probi...

متن کامل

Comparison of the Efficacies of 0.94 mm and Double Silicone Tubes for Treatment of Canalicular Obstruction

PURPOSE To compare the clinical effects of the single wide-diameter bicanalicular silicone tube and the double bicanalicular silicone tube in endonasal dacryocystorhinostomy (DCR) with canalicular trephinization for canalicular obstruction. METHODS We retrospectively reviewed the records of 121 patients with monocanalicular or common canalicular obstruction who had undergone endonasal DCR wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012