Electron-capturing derivatization of neutral steroids for increasing sensitivity in liquid chromatography/negative atmospheric pressure chemical ionization-mass spectrometry.

نویسندگان

  • Tatsuya Higashi
  • Natsuko Takido
  • Akinori Yamauchi
  • Kazutake Shimada
چکیده

Derivatization of neutral steroids for increasing sensitivity in liquid chromatography/negative atmospheric pressure chemical ionization-mass spectrometry (APCI-MS) has been examined. Under APCI conditions, gas-phase electrons are provided by the corona discharge and captured by electron-affinitive compounds. In negative APCI-MS, therefore, ultrahigh sensitivity can be obtained by tagging neutral steroids, whose ionization efficiencies are low in the conventional APCI-MS, with electron-capturing moieties, such as a nitro group. We synthesized various boronic acid and hydrazine derivatives having electron-capturing moieties as derivatization reagents for 1,2-diol compounds and oxosteroids, respectively. Among reagents examined, those having the 2-nitro-4-trifluoromethylphenyl moiety were most effective in increasing sensitivity. That is, the detection responses of the derivatives with these reagents were increased by several to more than 200-fold over intact steroids, where limits of detection were some picograms. The developed derivatization procedures were applied to analyses of small amounts of steroids in human plasma and gave satisfactory results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Derivatization in liquid chromatography/mass spectrometric analysis of neurosteroids.

Liquid chromatography/mass spectrometry (LC/MS) is now considered to be the most promising analytical method for the determination of biological substances, especially nonvolatile or highly polar substances. However, some compounds do not show enough sensitivity in LC/MS and soft-ionization methods commonly used in LC/MS, such as electrospray ionization (ESI) and atmospheric pressure chemical i...

متن کامل

Application of 4-(4-nitrophenyl)-1,2,4-triazoline-3,5-dione to analysis of 25-hydroxyvitamin D3 in human plasma by liquid chromatography/electron capture atmospheric pressure chemical ionization-mass spectrometry.

The utility of 4-(4-nitrophenyl)-1,2,4-triazoline-3,5-dione (NPTAD) as a derivatization reagent in the analysis of 25-hydroxyvitamin D3 [25(OH)D3] using liquid chromatography/electron capture atmospheric pressure chemical ionization-mass spectrometry (LC/ECAPCI-MS) was examined. The derivatives of 25(OH)D3 with NPTAD underwent electron capture in the APCI source in the negative-ion mode and pro...

متن کامل

Chemical derivatization and mass spectral libraries in metabolic profiling by GC/MS and LC/MS/MS.

An overview is presented of gas chromatography/mass spectrometry (GC/MS) and liquid chromatography/mass spectrometry (LC/MS), the two major hyphenated techniques employed in metabolic profiling that complement direct 'fingerprinting' methods such as atmospheric pressure ionization (API) quadrupole time-of-flight MS, API Fourier transform MS, and NMR. In GC/MS, the analytes are normally derivati...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Sample Preparation and Liquid Chromatography-Tandem Mass Spectrometry for Multiple Steroids in Mammalian and Avian Circulation

Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sample preparation for simultaneous liquid chromatography--tandem mass spectrometry (LC-MS/MS) quantit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 18 12  شماره 

صفحات  -

تاریخ انتشار 2002