Peripheral Quantitative CT (pQCT) Using a Dedicated Extremity Cone-Beam CT Scanner.

نویسندگان

  • A A Muhit
  • S Arora
  • M Ogawa
  • Y Ding
  • W Zbijewski
  • J W Stayman
  • G Thawait
  • N Packard
  • R Senn
  • D Yang
  • J Yorkston
  • C O Bingham
  • K Means
  • J A Carrino
  • J H Siewerdsen
چکیده

PURPOSE We describe the initial assessment of the peripheral quantitative CT (pQCT) imaging capabilities of a cone-beam CT (CBCT) scanner dedicated to musculoskeletal extremity imaging. The aim is to accurately measure and quantify bone and joint morphology using information automatically acquired with each CBCT scan, thereby reducing the need for a separate pQCT exam. METHODS A prototype CBCT scanner providing isotropic, sub-millimeter spatial resolution and soft-tissue contrast resolution comparable or superior to standard multi-detector CT (MDCT) has been developed for extremity imaging, including the capability for weight-bearing exams and multi-mode (radiography, fluoroscopy, and volumetric) imaging. Assessment of pQCT performance included measurement of bone mineral density (BMD), morphometric parameters of subchondral bone architecture, and joint space analysis. Measurements employed phantoms, cadavers, and patients from an ongoing pilot study imaged with the CBCT prototype (at various acquisition, calibration, and reconstruction techniques) in comparison to MDCT (using pQCT protocols for analysis of BMD) and micro-CT (for analysis of subchondral morphometry). RESULTS The CBCT extremity scanner yielded BMD measurement within ±2-3% error in both phantom studies and cadaver extremity specimens. Subchondral bone architecture (bone volume fraction, trabecular thickness, degree of anisotropy, and structure model index) exhibited good correlation with gold standard micro-CT (error ~5%), surpassing the conventional limitations of spatial resolution in clinical MDCT scanners. Joint space analysis demonstrated the potential for sensitive 3D joint space mapping beyond that of qualitative radiographic scores in application to non-weight-bearing versus weight-bearing lower extremities and assessment of phalangeal joint space integrity in the upper extremities. CONCLUSION The CBCT extremity scanner demonstrated promising initial results in accurate pQCT analysis from images acquired with each CBCT scan. Future studies will include improved x-ray scatter correction and image reconstruction techniques to further improve accuracy and to correlate pQCT metrics with known pathology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting Trabecular Bone Stiffness from Clinical Cone-Beam CT and HR-pQCT Data; an In Vitro Study Using Finite Element Analysis

Stiffness and shear moduli of human trabecular bone may be analyzed in vivo by finite element (FE) analysis from image data obtained by clinical imaging equipment such as high resolution peripheral quantitative computed tomography (HR-pQCT). In clinical practice today, this is done in the peripheral skeleton like the wrist and heel. In this cadaveric bone study, fourteen bone specimens from the...

متن کامل

Design and Optimization of a Dedicated Cone-Beam CT System for Musculoskeletal Extremities Imaging

The design, initial imaging performance, and model-based optimization of a dedicated cone-beam CT (CBCT) scanner for musculoskeletal extremities is presented. The system offers a compact scanner that complements conventional CT and MR by providing sub-mm isotropic spatial resolution, the ability to image weight-bearing extremities, and the capability for integrated real-time fluoroscopy and dig...

متن کامل

WE-G-217BCD-04: Diagnostic Image Quality Evaluation of a Dedicated Extremity Cone- Beam CT Scanner: Pre-Clinical Studies and First Clinical Results.

PURPOSE To assess the diagnostic performance of a prototype cone-beam CT (CBCT) scanner developed for musculoskeletal extremity imaging. Studies involved controlled observer studies conducted subsequent to rigorous technical assessment as well as patient images from the first clinical trial in imaging the hand and knee. METHODS Performance assessment included: 1.) rigorous technical assessmen...

متن کامل

Image Analysis for Trabecular Bone Properties on Cone-Beam CT Data

...................................................................................................................................... 7 Populärvetenskaplig sammanfattning ...................................................................................... 9 List of publications ......................................................................................................................

متن کامل

A dedicated cone-beam CT system for musculoskeletal extremities imaging: design, optimization, and initial performance characterization.

PURPOSE This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopae...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of SPIE--the International Society for Optical Engineering

دوره 8672  شماره 

صفحات  -

تاریخ انتشار 2013