A Model for the Tear Film and Ocular Surface Temperature for Partial Blinks.

نویسندگان

  • Quan Deng
  • R J Braun
  • T A Driscoll
  • P E King-Smith
چکیده

In this paper, we investigate the dynamics of tear film and the associated temperature variation for partial blinks. We investigate the mechanism of fluid supply during partial blink cycles, and compare the film thickness with observation in vivo. We find that varying the thickness of the fluid layer beneath the moving upper lid improves the agreement for the in vivo measurement of tear film thickness after a half blink. By examining the flux of the fluid, we provide an explanation of this assumption. We also investigate the temperature dynamics both at the ocular surface and inside the simulated anterior chamber. Our simulation results suggest that the ocular surface temperature readjusts rapidly to normal temperature distribution after partial blinks.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between Corneal Sensation, Blinking, and Tear Film Quality.

PURPOSE To examine the possible role of corneal sensitivity and tear film quality in triggering a blink by investigating the relationship between blink rate, central corneal sensitivity threshold (CST), ocular surface temperature (OST), tear meniscus height (TMH), tear film quality (noninvasive tear break-up time [NIBUT]), and tear film lipid pattern under normal conditions. METHODS Forty-two...

متن کامل

Single-equation models for the tear film in a blink cycle: realistic lid motion.

We consider model problems for the tear film over multiple blink cycles that utilize a single equation for the tear film; the single non-linear partial differential equation that governs the film thickness arises from lubrication theory. The two models that we consider arise from considering the absence of naturally occurring surfactant and the case when the surfactant is strongly affecting the...

متن کامل

The effect of low humidity on the human tear film.

PURPOSE To investigate the effect of exposure to a low relative humidity (RH) environment on tear film physiology. METHOD A controlled environment chamber was used to create 2 different environmental conditions. Ambient temperature was constant in both conditions (21°C) while the RH was set at 40% at the normal condition and at 5% in the desiccating environment. Tear evaporation, noninvasive ...

متن کامل

Repeated measurements of dynamic tear distribution on the ocular surface after instillation of artificial tears.

PURPOSE To determine the repeatability of real-time optical coherence tomography (OCT) measurements of tear film thickness (TFT) and variables of tear film menisci. METHODS Forty eyes were imaged with a custom-built, real-time OCT to obtain heights, curvatures, and cross-sectional areas of upper and lower tear menisci simultaneously. The central TFT was indirectly determined as the difference...

متن کامل

Comparison of hyaluronic acid-containing topical eye drops with carbomer-based topical ocular gel as a tear replacement in canine keratoconjunctivitis sicca: A prospective study in twenty five dogs

The aim of this study was to evaluate the efficacy of a hyaluronic acid containing eye drop in ameliorating ocular surface pathology and discomfort in canine keratoconjunctivitis sicca (KCS). Twenty five dogs with KCS treated with a topical carbomer (CA)-based tear replacement gel were moved to treatment with a hyaluronic acid (HA)-containing tear replacement eye drop. Dogs were subject to a fu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interfacial phenomena and heat transfer

دوره 1 4  شماره 

صفحات  -

تاریخ انتشار 2013