The significance of changes in pupil size during straylight measurement and with varying environmental illuminance.

نویسندگان

  • Sonia Gholami
  • Nicolaas J Reus
  • Thomas J T P van den Berg
چکیده

PURPOSE In this work, we investigated the pupillary conditions during straylight measurement, and the potential effect this might have on the measured straylight. METHODS Five young (26-29-years-old) and 15 older (50-68-years-old) individuals participated in this study. First, the pupil diameter of both eyes was measured at three room illuminances. Next, straylight was assessed at two room illuminances. Simultaneously, the change in pupil size of the fellow eye was registered by a camera. RESULTS Pupil size decreased with room illuminance and with age (both p<0.05). The dependency of pupil size on age decreased as room illuminance increased (0.018mm/year at 4 lux, 0.014mm/year at 40 lux, and 0.008mm/year at 400 lux illuminances). However, during straylight measurement, pupil sizes hardly differed between 4 and 40 lux illuminances. Respective pupil sizes corresponded with 399 and 451 lux adaptation on average. No statistically significant difference was found between the straylight under the two illuminances with average R2=0.85, p<0.05. CONCLUSION We conclude that the illuminance of the examination room during straylight assessment does not affect the outcome in normal eyes. In fact, under mesopic and scotopic conditions, the luminance of the test field is so much higher than that of the room so that it determines the pupil size. Regardless of the lighting level, straylight measured in a laboratory, is valid for photopic pupils at an adaptation level corresponding with about 400 lux room illuminance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pupil size and retinal straylight in the normal eye.

PURPOSE Glare problems originating from bright lights are generally experienced more strongly at night. The typical disability glare is known to result from retinal straylight. In this study, the effects of pupil diameter and, especially in the case of small pupils, of eye wall translucency on the amount of retinal straylight were investigated. METHODS Straylight was measured as a function of...

متن کامل

Comparison of the Retinal Straylight in Pseudophakic Eyes with PMMA, Hydrophobic Acrylic, and Hydrophilic Acrylic Spherical Intraocular Lens

Purpose. To investigate the intraocular straylight value after cataract surgery. Methods. In this study, 76 eyes from 62 patients were subdivided into three groups. A hydrophobic acrylic, a hydrophilic acrylic, and a PMMA IOL were respectively, implanted in 24 eyes, 28 eyes, and 24 eyes. Straylight was measured using C-Quant at 1 week and 1 month postoperatively in natural and dilated pupils. R...

متن کامل

Straylight measurements in pseudophakic eyes with natural and dilated pupils: one-year follow-up.

PURPOSE To compare the amount of straylight in natural pupils and dilated pupils in pseudophakic eyes 6 weeks and 1 year after cataract extraction. SETTING Laboratory of Experimental Ophthalmology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands. METHODS This study evaluated patients with bilateral age-related cataract who had cataract surgery with i...

متن کامل

Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements.

PURPOSE To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with...

متن کامل

Prognosis of pseudophakic retinal detachment

Reply: We would like to thank Cheng et al. for their comments. The Zywave unit used by them (commercial software 5.09) is different from the one used in our study (software 4.45SP2). Using the pupillometry function, software 5.09 has no fixation target light and the infrared laser runs continuously at 2 mW of power during the measurement. Software 4.45SP2 has no fixation target light, and the i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of optometry

دوره   شماره 

صفحات  -

تاریخ انتشار 2017