Improved reconstruction for IDEAL spiral CSI
نویسندگان
چکیده
منابع مشابه
Accelerated reconstruction using parallel computing for spiral spectroscopic imaging
Introduction Over the years, the development of fast spectroscopic imaging techniques has found applications in full coverage CSI (chemical shift imaging) and/or high resolution CSI. Recently, the interest has continued with usage in areas such as real time metabolite imaging [1] and temperature mapping, which can be used in interventional procedures [2]. Of these fast spectroscopic imaging pro...
متن کاملMagnetic resonance spectroscopic imaging using parallel transmission at 7T
Conventional magnetic resonance spectroscopic imaging (MRSI), also known as phase-encoded (PE) chemical shift imaging (CSI), suffers from both low signal-to-noise ratio (SNR) of the brain metabolites, as well as inflexible tradeoffs between acquisition time and spatial resolution. In addition, although CSI at higher main field strengths, e.g. 7 Tesla (T), offers improved SNR over clinical 1.5T ...
متن کاملFast parallel spiral chemical shift imaging at 3T using iterative SENSE reconstruction.
Spiral chemical shift imaging (CSI) is a fast CSI technique that simultaneously encodes 1D spectral and 2D spatial information. Therefore, it potentially allows one to perform a 2D-CSI experiment in a single shot. However, for most applications, limitations on maximum gradient strength and slew rate make multiple excitations necessary in order to achieve a desired spectral bandwidth. In this wo...
متن کاملDetection of 3D Cardiac metabolism after injection of hyperpolarized [1-13C]pyruvate
Methods Three healthy male mini-pigs (38±2 kg) were maintained under deep sedation; a dose of 20 mL of 230 mM [1-13C]pyruvate was administered over about 10 s by manual injection. Animal experiments were performed on a 3T GE Signa HDx scanner with a 13C quadrature birdcage coil. [1-13C]pyruvate was polarized using a HyperSense DNP polariser with subsequent dissolution. The final injection solut...
متن کاملNonconvex optimization for improved exploitation of gradient sparsity in CT image reconstruction
A nonconvex optimization algorithm is developed, which exploits gradient magnitude image (GMI) sparsity for reduction in the projection view angle sampling rate. The algorithm shows greater potential for exploiting GMI sparsity than can be obtained by convex total variation (TV) based optimization. The nonconvex algorithm is demonstrated in simulation with ideal, noiseless data for a 2D fan-bea...
متن کامل