Improved reconstruction for IDEAL spiral CSI

نویسندگان

  • Rie B Hansen
  • Christoffer Laustsen
  • Rolf F Schulte
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerated reconstruction using parallel computing for spiral spectroscopic imaging

Introduction Over the years, the development of fast spectroscopic imaging techniques has found applications in full coverage CSI (chemical shift imaging) and/or high resolution CSI. Recently, the interest has continued with usage in areas such as real time metabolite imaging [1] and temperature mapping, which can be used in interventional procedures [2]. Of these fast spectroscopic imaging pro...

متن کامل

Magnetic resonance spectroscopic imaging using parallel transmission at 7T

Conventional magnetic resonance spectroscopic imaging (MRSI), also known as phase-encoded (PE) chemical shift imaging (CSI), suffers from both low signal-to-noise ratio (SNR) of the brain metabolites, as well as inflexible tradeoffs between acquisition time and spatial resolution. In addition, although CSI at higher main field strengths, e.g. 7 Tesla (T), offers improved SNR over clinical 1.5T ...

متن کامل

Fast parallel spiral chemical shift imaging at 3T using iterative SENSE reconstruction.

Spiral chemical shift imaging (CSI) is a fast CSI technique that simultaneously encodes 1D spectral and 2D spatial information. Therefore, it potentially allows one to perform a 2D-CSI experiment in a single shot. However, for most applications, limitations on maximum gradient strength and slew rate make multiple excitations necessary in order to achieve a desired spectral bandwidth. In this wo...

متن کامل

Detection of 3D Cardiac metabolism after injection of hyperpolarized [1-13C]pyruvate

Methods Three healthy male mini-pigs (38±2 kg) were maintained under deep sedation; a dose of 20 mL of 230 mM [1-13C]pyruvate was administered over about 10 s by manual injection. Animal experiments were performed on a 3T GE Signa HDx scanner with a 13C quadrature birdcage coil. [1-13C]pyruvate was polarized using a HyperSense DNP polariser with subsequent dissolution. The final injection solut...

متن کامل

Nonconvex optimization for improved exploitation of gradient sparsity in CT image reconstruction

A nonconvex optimization algorithm is developed, which exploits gradient magnitude image (GMI) sparsity for reduction in the projection view angle sampling rate. The algorithm shows greater potential for exploiting GMI sparsity than can be obtained by convex total variation (TV) based optimization. The nonconvex algorithm is demonstrated in simulation with ideal, noiseless data for a 2D fan-bea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017