Radial head replacement with a bipolar system: a minimum 2-year follow-up.

نویسندگان

  • Mark R Zunkiewicz
  • Jill S Clemente
  • Mark C Miller
  • Mark E Baratz
  • Robert W Wysocki
  • Mark S Cohen
چکیده

BACKGROUND We report the short-term results of a cohort of patients undergoing radial head replacement using a novel radial head prosthesis with a smooth, unfixed, telescoping stem and a bipolar design after a mean follow-up of 34 months (range, 24-48 months). MATERIALS AND METHODS Patients were assessed using clinical and radiographic examination as well as with standardized outcome measures. Thirty implants (29 patients) were available for review. RESULTS At final follow-up, the average Mayo Elbow Performance Index Score was 92.1 and the Disabilities of the Arm, Shoulder, and Hand Score was 13.8. Clinical examination revealed significant differences between operative and nonoperative sides for flexion/extension and pronation/supination. Radiographic measurement of medial and lateral ulnohumeral spaces revealed re-establishment of a congruent elbow joint. No significant arthritic changes were identified at the radiocapitellar joint. Minimal angular migration of the implant in the proximal radial shaft was observed over time. Complications included 1 patient requiring temporary placement of a hinged external fixator for instability and 1 patient requiring revision surgery at 4 weeks. CONCLUSION This review demonstrates that a bipolar radial head prosthesis with a smooth stem and telescoping neck effectively restores stability to elbows with a comminuted radial head fracture and valgus instability. To date, this is the largest reported outcome analysis of bipolar radial head replacement in the literature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiographic Predictors for Short-term Functional Outcome after Radial Head Arthroplasty in Patients with Persistent Symptoms after Treatment for Radial Head

Background: Evaluation of the accurate position after radial head arthroplasty remains a challenge for surgeons.Standard radiographs are used to evaluate the position of the implant, however, results regarding radiographicdeficiencies on clinical outcome are not consistent. In this retrospective study our main aim was to determine if subtleradiographic deficiencies after radia...

متن کامل

Evaluation of Radiocapitellar Arthritis in Patients with a Second Radiograph at Least 2 Years after Nonoperative Treatment of an Isolated Radial Head Fracture

Background: To study if patients that have a second radiograph 2 or more years after nonoperative treatment of an isolated radial head fracture have radiocapitellar osteoarthritis (RC OA). Methods: We used the database of 3 academic hospitals in one health system from 1988 to 2013 to find patients with isolated radial head fractures (no associated ligament injury or fracture) that had a second ...

متن کامل

A dislocation of the inner head in bipolar prosthesis with a self-centering system: a case report.

We present a case of inner head dislocation 11 years after the replacement of a bipolar prosthesis with a self-centering system. An 84-year-old woman with osteoarthritis of the left hip underwent a replacement of the Bateman UPF-II bipolar prosthesis in 1987. She fell off a chair on April 19 1998, and felt a sudden sharp pain in the left hip. Roentgenograms revealed that the inner head was disl...

متن کامل

Is the stemless humeral head replacement clinically and radiographically a secure equivalent to standard stem humeral head replacement in the long-term follow-up? A prospective randomized trial.

BACKGROUND Stemless humeral head replacement represents a young generation of shoulder arthroplasty. This study evaluated the differences of this new stemless design compared with the fourth-generation standard stemmed design. METHODS Total shoulder arthroplasty was performed in 20 patients with a stemless shoulder prosthesis (group 1) and in 20 patients with a standard stem humeral head repl...

متن کامل

A floating prosthesis for radial-head fractures.

We report our experience over seven years with a floating radial-head prosthesis for acute fractures of the radial head and the complications which may result from such injury. The prosthesis has an integrated articulation which allows change of position during movement of the elbow. We present the results in 12 patients with a minimum follow-up of two years. Five prostheses had been implanted ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2012