A Novel Algorithm for Movement Artifact Removal in ECG Signals Acquired from Wearable Systems Applied to Horses

نویسندگان

  • Antonio Lanata
  • Andrea Guidi
  • Paolo Baragli
  • Gaetano Valenza
  • Enzo Pasquale Scilingo
  • Leontios Hadjileontiadis
چکیده

This study reports on a novel method to detect and reduce the contribution of movement artifact (MA) in electrocardiogram (ECG) recordings gathered from horses in free movement conditions. We propose a model that integrates cardiovascular and movement information to estimate the MA contribution. Specifically, ECG and physical activity are continuously acquired from seven horses through a wearable system. Such a system employs completely integrated textile electrodes to monitor ECG and is also equipped with a triaxial accelerometer for movement monitoring. In the literature, the most used technique to remove movement artifacts, when noise bandwidth overlaps the primary source bandwidth, is the adaptive filter. In this study we propose a new algorithm, hereinafter called Stationary Wavelet Movement Artifact Reduction (SWMAR), where the Stationary Wavelet Transform (SWT) decomposition algorithm is employed to identify and remove movement artifacts from ECG signals in horses. A comparative analysis with the Normalized Least Mean Square Adaptive Filter technique (NLMSAF) is performed as well. Results achieved on seven hours of recordings showed a reduction greater than 40% of MA percentage (between before- and after- the application of the proposed algorithm). Moreover, the comparative analysis with the NLMSAF, applied to the same ECG recordings, showed a greater reduction of MA percentage in favour of SWMAR with a statistical significant difference (p-value < 0.0.5).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact Removal from Biosignal using Fixed Point ICA Algorithm for Pre-processing in Biometric Recognition

In the modern world of automation, biological signals, especially Electroencephalogram (EEG) and Electrocardiogram (ECG), are gaining wide attention as a source of biometric information. Earlier studies have shown that EEG and ECG show versatility with individuals and every individual has distinct EEG and ECG spectrum. EEG (which can be recorded from the scalp due to the effect of millions of n...

متن کامل

A Wearable System for the Evaluation of the Human-Horse Interaction: A Preliminary Study

This study reports on a preliminary estimation of the human-horse interaction through the analysis of the heart rate variability (HRV) in both human and animal by using the dynamic time warping (DTW) algorithm. Here, we present a wearable system for HRV monitoring in horses. Specifically, we first present a validation of a wearable electrocardiographic (ECG) monitoring system for horses in term...

متن کامل

Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful.Objective: Removing electrocardiogram contamination from electromyogram signals.Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and e...

متن کامل

Comparative Analysis of PCA and Wavelet based Motion Artifact Detection and Spectral Characterization in W-ECG

The use of wearable ECG recorders is becoming common nowadays for the people suffering from cardiac disorders. Although it is a convenient option for hospitalization, it has an inherent drawback of recorded ECG being contaminated by motion artifacts due to various body movement activities of the wearer. In this paper, the spectral characteristics of motion artifacts occurring in wearable ECG (W...

متن کامل

Implementation of Fuzzy-rule based Activity Classification and Optimized Adaptive Filter-set for Wearable ECG Recording

An enhanced and optimized adaptive filter with optimal filter coefficients selection is proposed and implemented to resolve motion artifact issue in wearable ECG Recording. A two-electrode small size chest belt ECG system mounted with 3-axis accelerometer is implemented for ECG and activity ubiquitous recording in daily life. In ubiquitous ECG recording, ECG signal is often distorted due to dif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015