Accidental transection of a radial artery cannula.

نویسندگان

  • Umar Imran Hamid
  • Anton Collins
  • Chris McConkey
  • Pushpinder Sidhu
چکیده

DESCRIPTION Continuous display of arterial waveform is a useful adjunct in monitoring of complex surgical cases. The nondominant radial artery is the vessel of choice in the absence of peripheral vascular disease. A patient underwent an aortic valve replacement and coronary artery bypass grafts. On postoperative day 2, while cutting the dressing surrounding the radial artery 20-gauge BD insyte cannula (Becton Dickinson, Swindon, UK), it was accidently transected. Bleeding led to the application of digital pressure. This caused migration of the transected cannula into the radial artery. A retained fragment located completely within the radial artery was confirmed with ultrasound imaging using Sonosite (SonoSite Inc, Bothell, Washington, USA). Initial attempt was made to retrieve it surgically but failed to localise the cannula. On subsequent x-ray imaging of the hand (figure 1), the cannula had migrated distally and could be seen at the base of the first metacarpal. The patient was asymptomatic with no evidence of ischaemia in the hand. The transected cannula was then retrieved percutaneously. Access was gained to the left brachial artery above the level of the elbow joint under ultrasonic guidance using a micropuncture set. A 5-French sheath was then placed. A 4-French guide catheter was negotiated into the right radial artery. Angiography confirmed the presence of the foreign body within the distal radial artery (figure 2). The cannula was removed using a snare (Micro Elite 4 mm Vascular Solutions; figure 3). Checked angiography showed some spasm but no other abnormality. Haemostasis was achieved using manual compression. No complications arose in the hand following removal of cannula. Distal embolisation of foreign bodies are uncommon and result from missile injuries. The concern associated with embolisation of foreign bodies is distal ischaemia and should be retrieved if possible. Transection of radial artery cannula is rare. In similar cases reported, an arterial line fractured during suturing, and ultrasound was used to localise the foreign body. Percutaneous retrieval of intravascular foreign bodies is not a new concept, snares are of often used when the foreign body has a free end or doubled-over segment that

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Apparent hyperkalaemia from blood sampled from an arterial cannula.

Blood samples were obtained from a radial artery cannula in a 60-yr-old man during coronary artery surgery. Serum potassium concentrations of 9.3, 8.4, and 7.4 mmol litre(-1) were obtained. A simultaneous venous blood sample gave a serum potassium concentration of 4.4 mmol litre(-1). The ECG was unchanged. After the arterial cannula was repositioned, subsequent blood samples gave expected range...

متن کامل

Axillary artery cannulation

Percutaneous cannulation of the axillary artery is a safe and appropriate means of intervention for invasive blood pressure monitoring, particularly in the absence of radial or other peripheral pulses. On five separate occasions the author was called upon to place an indwelling cannula for continuous blood pressure monitoring for patients in whom no distal peripheral pulses were palpable. In ea...

متن کامل

Effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization

OBJECTIVE The purpose of this study was to evaluate the effectiveness of a compressive device in controlling hemorrhage following radial artery catheterization. METHODS A prospective randomized trial was conducted on subjects receiving the standard taping method (group S) compared to a compressive device method (group C) after removal of the cannula in radial artery catheterization. Primary o...

متن کامل

Neurological Study of Radial Nerve Conduction During Endoscopic Radial Artery Harvesting:An Intra‐Operative Evaluation

Endoscopic radial artery harvesting (ERAH) is a feasible and attractive minimally invasive approach for conduit procurement, however there have been concerns about a potential neurological damage occurring at the harvest limb site secondary to injury of the radial nerve during endoscopic harvesting. We present a case of ERAH in which we evaluated intraoperatively the characteristics of radial n...

متن کامل

Radial neuropathy following arterial line removal: A rare complication from a routine ICU procedure

Radial artery thrombosis is a rare complication of cannulation. There are no reported cases of acute thrombosis and severe acute neuropathy in the setting of cannula discontinuation. We report a case of acute radial nerve mono-neuropathy following thrombosis after radial arterial line removal. The thrombus was immediately evident on exam and diagnostic imaging after cannula discontinuation. The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMJ case reports

دوره 2012  شماره 

صفحات  -

تاریخ انتشار 2012