Medial Pivot in Total Knee Arthroplasty: Literature Review and Our First Experience

نویسندگان

  • Luigi Sabatini
  • Salvatore Risitano
  • Gennaro Parisi
  • Ferdinando Tosto
  • Pier Francesco Indelli
  • Francesco Atzori
  • Alessandro Massè
چکیده

Background Traditional total knee implants designs, usually, are not able to reproduce the physiological kinematics of the knee, leaving almost 20% of the patients, those who underwent a total knee arthroplasty (TKA), not fully satisfied. Modern inserts are nowadays designed with a fully congruent medial compartment to reproduce the normal medial pivoting biomechanics of the knee. The aim of this article was to evaluate preliminary clinical improvement using the Medial Congruent (MC) insert as specific level of constraint. Materials and methods A total of 10 consecutive patients have been enrolled in this study and treated using an MC tibial polyethylene insert. The Oxford Knee Score (OKS) and the Knee Society Score (KSS) have been assessed preoperatively and at 3-month, 6-month, and 1-year follow-up (FU) and used as validated measurements to evaluate early clinical improvements. Postoperative radiological examination was reviewed looking for radiolucent lines or loosening of the components. Results Average improvement in OKS was from 19.5 to 41.2, whereas KSS improved with an average score from 64.7 preoperatively to 167.5 at the final FU showing good to excellent results in 95% of the treated knees. Evaluating the range of motion, the average maximum active movement was 124° and none of the patients needing for a revision surgery or manipulation under anesthesia. No complications were observed at the final FU as septic or aseptic loosening or vascular or neurologic injury. Discussion and conclusions Medial Congruent insert showed good to excellent clinical results at 1-year FU. Range of motion and subjective outcomes were satisfying and comparable with results obtained in literature using traditional TKA design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does a Previous High Tibial Osteotomy (HTO) Influence the Long-term Function or Survival of a Total Knee Arthroplasty (TKA)?

 High tibial osteotomy (HTO) is a well established technique for the treatment of medial osteoarthritis ofthe knee with varus malalignment. The outcome of total knee arthroplasty (TKA) after HTO remains uncertain.The aim of this paper is to revise the literature with the aim of answering the following question: Does a previous (HTO)influence the long-term function or survival of a TKA?. The sea...

متن کامل

Correlation between knee kinematics and patellofemoral contact pressure in total knee arthroplasty.

The aim of this study is to evaluate the relationship between patellofemoral contact stress and intraoperative knee kinematic patterns after mobile bearing total knee arthroplasty (TKA). Medial osteoarthritic knees of forty-six posterior-stabilized total knee prostheses were evaluated using a computed tomography-guided navigation system. Subjects were divided into two groups based on intraopera...

متن کامل

Medial pivot knee in primary total knee arthroplasty.

Total knee arthroplasty (TKA) with a medial pivot design was developed in order to mimic normal knee kinematics; the highly congruent medial compartment implant should improve clinical results and decrease contact stresses. Clinical and radiographic mid-term outcomes are satisfactory, but we need other studies to evaluate long-term results and indications for unusual cases.

متن کامل

Conservative Bone Cuts and Technical Hints Incruciate Retaining Total Knee Arthroplasty, a 20 Years Experience

Total knee arthroplasty (TKA) is one of the most successful procedures in modern orthopedic surgery, providing high patient satisfaction rate. As a result, the number of patients undergoing TKA is increasing in number every year and more patients would be inclined to have the operation in near future . The demand for TKA is expected to grow 673% between 2005 and 2030. Knee surgeons are using mo...

متن کامل

Polyethylene wear particles in synovial fluid after total knee arthroplasty.

The aims of the current study were to examine polyethylene particles in synovial fluid at an early stage, and to compare a newly introduced medial pivot total knee prosthesis with an established posterior-stabilized total knee prosthesis. Synovial fluid was obtained 1 year after knee arthroplasty from 17 patients with well-functioning prostheses (22 knees, 11 posterior-stabilized prostheses and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2018