User vs. software-dependent variability of ELISPOT counts obtained from ten different laboratories

نویسندگان

  • Tameem Ansari
  • Alexey Karulin
  • Paul V Lehmann
  • Srividya Sundararaman
چکیده

Introduction In each human donor’s PBMC, there is a defined number of T cells specific for any given antigen. A major goal of immune monitoring with ELISPOT is to measure this number accurately and reproducibly between different laboratories. In ELISPOT assays, cytokine spots produced by antigen-specific T cells show a broad spectrum of sizes and densities over variable background. Therefore, even experienced investigators are likely to come up with different spot counts when subjectively judging the minimal spot size/density to be counted and the maximal spot size for the cut off between single-cell-derived spots vs. those created by cell clusters. This study aims to find out whether statistics-based automated gating can harmonize spot counts obtained in different laboratories.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Reproducibility of ELISPOT Counts from Nine Different Laboratories

The primary goal of immune monitoring with ELISPOT is to measure the number of T cells, specific for any antigen, accurately and reproducibly between different laboratories. In ELISPOT assays, antigen-specific T cells secrete cytokines, forming spots of different sizes on a membrane with variable background intensities. Due to the subjective nature of judging maximal and minimal spot sizes, dif...

متن کامل

Log-Normal ELISPOT spot size distribution permits count harmonization among different laboratories

Introduction ELISPOT assays are primarily used to detect the number of T cells that respond to a given antigen. With that number being absolute for any given donor sample, ELISPOT counts should be similar between laboratories, if subjectivity in counting is avoided. Due to the differences in spot sizes ranging from microns to millimeters, setting cut offs for minimal and maximal spot sizes will...

متن کامل

Identification of Major Factors Influencing ELISpot-Based Monitoring of Cellular Responses to Antigens from Mycobacterium tuberculosis

A number of different interferon-gamma ELISpot protocols are in use in laboratories studying antigen-specific immune responses. It is therefore unclear how results from different assays compare, and what factors most significantly influence assay outcome. One such difference is that some laboratories use a short in vitro stimulation period of cells before they are transferred to the ELISpot pla...

متن کامل

NEW OR RARE CHROMOSOME COUNTS IN TEN SPECIES OF COUSINIA FROM IRAN (I)

The meiotic chromosome counts are reported in 10 species of the genus Cousinia including: C. adenostegia, C. antonowii, C. chaetocephala, C. dasylepis, C. eriobasis, C. freynii, C. prasina, C. rechingerorum, C. termei and C. trachyphyllaria from Iran. Specimens have been collected from different parts of Iran out of which, eight species are considered to be new and two provide confirmation of t...

متن کامل

Design, Implementation and Evaluation of Software to Increase Users’ Awareness and Facilitate the Identification of the Most Appropriate Centers Providing Laboratory Services in Tehran Province

Background and Aim: Medical diagnostic laboratories are among the most important centers in the treatment cycle of patients. Today, the conscious choice of such laboratories is one of the challenges that patients face in the treatment process. This study was conducted with the aim of improving the knowledge of software users in the field of laboratory sciences and also facilitating the consciou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2013