Comparison of mouse and rabbit lung damage exposure to 30 kHz ultrasound.

نویسندگان

  • W D O'Brien
  • J F Zachary
چکیده

Twenty-four mice and sixteen rabbits were evaluated at one exposure duration (10 min) and at three exposure acoustic pressure levels (0, 100 and 145 kPa) at an ultrasonic frequency of 30 kHz, continuous wave for the purpose of testing whether there was a species difference in the degree of sensitivity to ultrasound-induced lung damage. This study was undertaken because it was hypothesized that the mouse may not be an acceptable or suitable animal model for studies that examine the effects of ultrasound on lung tissue for purposes of extrapolating or estimating the degree of potential damage in other species. The rabbit was selected for comparison to the mouse because the rabbit exhibited sufficient physiological and morphological differences from those of the mouse to test this hypothesis. Using exactly the same exposure conditions and lung assessment criteria, it appeared that the mouse lung was more sensitive to ultrasound-induced damage than that of the rabbit by a factor of between 2.8 and 3.6. Lung lesions in mice and rabbits were similar in character, but were much more severe and extensive in mice. Lesions in both species consisted of intraalveolar hemorrhage that appeared as dark red to red-black areas that were visible on the pleural surfaces and that extend within the lung parenchyma.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mouse lung damage from exposure to 30 kHz ultrasound.

Two hundred and seventy mice were evaluated at three exposure durations (5, 10 and 20 min) and at six peak acoustic pressure levels (0, 65, 80, 87, 100 and 145 kPa) with 15 mice per exposure condition, at an ultrasonic frequency of 30 kHz modulated at 120 Hz. Threshold acoustic pressure levels for hemorrhage in mouse lung exposed for the three exposure durations appear to be in the range of 100...

متن کامل

Threshold estimation of ultrasound-induced lung hemorrhage in adult rabbits and comparison of thresholds in mice, rats, rabbits and pigs.

The objective of this study was to assess the threshold and superthreshold behavior of ultrasound (US)-induced lung hemorrhage in adult rabbits to gain greater understanding about species dependency. A total of 99 76 +/- 7.6-d-old 2.4 +/- 0.14-kg New Zealand White rabbits were used. Exposure conditions were 5.6-MHz, 10-s exposure duration, 1-kHz PRF and 1.1-micros pulse duration. The in situ (a...

متن کامل

Comparison the treatment effects between simultaneous dual frequency and single frequency irradiation of ultrasound in a murine model of breast adenocarcinoma

Introduction: Transient cavitations induced by low frequency irradiation of ultrasound can be used to treat tumors. Previous studies in in-vitro experiments have shown that induced cavitation by dual or multiple frequencies of ultrasound is greater than induced cavitation by single frequency irradiation. In this study, we compared and evaluated the treatment effects of dual frequency irradiatio...

متن کامل

Effects of pulsed ultrasound on the mouse neonate: hind limb paralysis and lung hemorrhage.

Exposure conditions were determined for hind limb paralysis and lung hemorrhage of neonatal mice due to pulsed exposure (10 microsecond pulse duration) to 1 MHz focused ultrasound. Spatial peak pulse average intensity and peak rarefactional pressure levels for paralysis in 50% of specimens sonicated were determined for pulse repetition frequencies of 1, 5 and 50 kHz at 10 degrees C and 2.4 s ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 1994