Automated control of mechanical ventilation during general anaesthesia: study protocol of a bicentric observational study (AVAS)
نویسندگان
چکیده
INTRODUCTION Automated control of mechanical ventilation during general anaesthesia is not common. A novel system for automated control of most of the ventilator settings was designed and is available on an anaesthesia machine. METHODS AND ANALYSIS The 'Automated control of mechanical ventilation during general anesthesia study' (AVAS) is an international investigator-initiated bicentric observational study designed to examine safety and efficacy of the system during general anaesthesia. The system controls mechanical breathing frequency, inspiratory pressure, pressure support, inspiratory time and trigger sensitivity with the aim to keep a patient stable in user adoptable target zones. Adult patients, who are classified as American Society of Anesthesiologists physical status I, II or III, scheduled for elective surgery of the upper or lower limb or for peripheral vascular surgery in general anaesthesia without any additional regional anaesthesia technique and who gave written consent for study participation are eligible for study inclusion. Primary endpoint of the study is the frequency of specifically defined adverse events. Secondary endpoints are frequency of normoventilation, hypoventilation and hyperventilation, the time period between switch from controlled ventilation to assisted ventilation, achievement of stable assisted ventilation of the patient, proportion of time within the target zone for tidal volume, end-tidal partial pressure of carbon dioxide as individually set up for each patient by the user, frequency of alarms, frequency distribution of tidal volume, inspiratory pressure, inspiration time, expiration time, end-tidal partial pressure of carbon dioxide and the number of re-intubations. ETHICS AND DISSEMINATION AVAS will be the first clinical study investigating a novel automated system for the control of mechanical ventilation on an anaesthesia machine. The study was approved by the ethics committees of both participating study sites. In case that safety and efficacy are acceptable, a randomised controlled trial comparing the novel system with the usual practice may be warranted. TRIAL REGISTRATION DRKS DRKS00011025, registered 12 October 2016; clinicaltrials.gov ID. NCT02644005, registered 30 December 2015.
منابع مشابه
بررسی عوامل بیهوشی عمومی با ماسک در بیماران تحت عمل جراحی در یکی از بیمارستانهای وابسته به دانشگاه علوم پزشکی ایران(1372)
This research project is a field study to investigate the complications of general anaesthesia with mask in patients under surgery in a hospital affiliated to University of Medical Sciences Iran. The specific goals of this study are as follows: -To determine some of the characters of patients under study. -To determine the complications of general anesthesia with mask during surgery in on...
متن کاملThe effect of protocol of weaning from mechanical ventilation on gastrointestinal function in people undergoing coronary artery bypass graft surgery (CABG)
Abstract Aim. The aim of this study was to examine the effect of protocol of weaning from mechanical ventilation on the gastrointestinal function in people undergoing CABG. Background. The most common problems after cardiac surgery in the intensive care unit are change in vital signs, respiratory problems, unsuccessful separation from mechanical ventilation, and gastrointestinal problems. Due t...
متن کاملAnaesthesia modalities during laser photocoagulation for retinopathy of prematurity: a retrospective, longitudinal study
OBJECTIVES Laser photocoagulation surgery is a routine treatment for threshold retinopathy of prematurity (ROP). However, little is known about which anaesthesia protocols provide efficient pain control while minimising exposure risk to vulnerable infants. In this study, therefore, we assessed the efficacy and tolerability of multiple anaesthesia techniques used on premature infants during lase...
متن کاملFuzzy logic control of mechanical ventilation during anaesthesia.
We have examined a new approach, using fuzzy logic, to the closed-loop feedback control of mechanical ventilation during general anaesthesia. This control system automatically adjusts ventilatory frequency (f) and tidal volume (VT) in order to achieve and maintain the end-tidal carbon dioxide fraction (FE'CO2) at a desired level (set-point). The controller attempts to minimize the deviation of ...
متن کاملInvestigation of the Paediatric Tracheostomy Decannulation: Factors Affecting Outcome
Introduction: Evidence for factors determining paediatric tracheostomy decannulation vary extensively; therefore, this prospective observational study aimed to investigate these factors. Materials and Methods: In total, 67 consecutive paediatric patients (<12 years old) who referred to the Department of Otolaryngology, (Postgraduate Institute Medical Education and Research),(Chandigarh), ...
متن کامل