Grading nuclear cataract: reproducibility and validity of a new method.

نویسندگان

  • N F Hall
  • P Lempert
  • R P Shier
  • R Zakir
  • D Phillips
چکیده

AIMS To assess the reproducibility and validity of a new instrument for grading nuclear cataract-the laser slit lamp, by comparison with an established method of lens grading-the Lens Opacities Classification System III (LOCS III). METHODS 62 volunteers (113 eyes) were examined on two occasions. At each visit, a video image of the anterior segment was captured with the laser slit lamp and stored digitally. A measure of lens opacity for each laser slit lamp image was calculated using image analysis software. Each lens was also photographed on both visits for LOCS III grading of nuclear colour and nuclear opalescence. RESULTS There was a linear increasing relation between the laser slit lamp measure of nuclear lens opacity and the LOCS III nuclear opalescence scores. The overall reproducibility of the laser slit lamp measurement was comparable with LOCS III (intraclass correlation coefficient of 95% (95% CI 92.9-96.5) for the laser slit lamp method; 97% (95% CI 95. 6-97.9) for the LOCS III method). However, among healthy subjects, the reproducibility was lower (intraclass correlation for the laser slit lamp of 38.6% (95% CI 12.9-59.2) and 76.1% (95% CI 62.3-85.4) for LOCS III. CONCLUSION The laser slit lamp appears to give a valid measurement of nuclear cataract. The reproducibility of the instrument was high and similar to that of LOCS III. Modifications to the design would have to be made to improve its reproducibility among healthy subjects. It is simpler than other objective instruments, and could be useful in large scale studies of cataract.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitating nuclear opacification in color Scheimpflug photographs.

PURPOSE To test the validity of the color component subtraction method, a new objective technique of measuring nuclear cataract, and to correlate the tangent values of the different degrees of nuclear opacities to their corresponding subjective nuclear cataract grading using the Lens Opacities Classification System II and to another objective method of measuring nuclear cataract. METHODS Dens...

متن کامل

Validity of a new computer-aided diagnosis imaging program to quantify nuclear cataract from slit-lamp photographs.

PURPOSE To validate a new computer-aided diagnosis (CAD) imaging program for the assessment of nuclear lens opacity. METHODS Slit-lamp lens photographs from the Singapore Malay Eye Study (SiMES) were graded using both the CAD imaging program and manual assessment method by a trained grader using the Wisconsin Cataract Grading System. Cataract was separately assessed clinically during the stud...

متن کامل

Validation of the Nuclear Cataract Grading System BCN 10.

PURPOSE To evaluate a new nuclear cataract grading system which is intended as a surgical guidance system to predict lens hardness before cataract surgery. METHODS The new BCN 10 grading system consists of frontal and cross-sectional slit-lamp images of human eye lenses, ranging from a completely transparent lens nucleus to a totally black nuclear cataract. Validation was done with 9 observer...

متن کامل

The Clinical Validity of Disc Degeneration on a Magnetic Resonance Imaging for the Lumbar Related Symptoms

Objective: To assess the clinical validity of a new grading system based on T2weighted magnetic resonance imaging (MRI) for lumbar disc degeneration Study Design: Retrospective study Overview of the Literature: Various MRI classification criteria have been widely used for evaluation of intervertebral disc pathology. However, there is still considerable controversy regarding the MRI factors that...

متن کامل

Image based grading of nuclear cataract by SVM regression

Cataract is one of the leading causes of blindness worldwide. A computer-aided approach to assess nuclear cataract automatically and objectively is proposed in this paper. An enhanced Active Shape Model (ASM) is investigated to extract robust lens contour from slit-lamp images. The mean intensity in the lens area, the color information on the central posterior subcapsular reflex, and the profil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 83 10  شماره 

صفحات  -

تاریخ انتشار 1999