Implant Size and Fixation Mode Strongly Influence Tissue Reactions in the CNS

نویسندگان

  • Jonas Thelin
  • Henrik Jörntell
  • Elia Psouni
  • Martin Garwicz
  • Jens Schouenborg
  • Nils Danielsen
  • Cecilia Eriksson Linsmeier
چکیده

The function of chronic brain machine interfaces depends on stable electrical contact between neurons and electrodes. A key step in the development of interfaces is therefore to identify implant configurations that minimize adverse long-term tissue reactions. To this end, we here characterized the separate and combined effects of implant size and fixation mode at 6 and 12 weeks post implantation in rat (n = 24) cerebral cortex. Neurons and activated microglia and astrocytes were visualized using NeuN, ED1 and GFAP immunofluorescence microscopy, respectively. The contributions of individual experimental variables to the tissue response were quantified. Implants tethered to the skull caused larger tissue reactions than un-tethered implants. Small diameter (50 µm) implants elicited smaller tissue reactions and resulted in the survival of larger numbers of neurons than did large diameter (200 µm) implants. In addition, tethering resulted in an oval-shaped cavity, with a cross-section area larger than that of the implant itself, and in marked changes in morphology and organization of neurons in the region closest to the tissue interface. Most importantly, for implants that were both large diameter and tethered, glia activation was still ongoing 12 weeks after implantation, as indicated by an increase in GFAP staining between week 6 and 12, while this pattern was not observed for un-tethered, small diameter implants. Our findings therefore clearly indicate that the combined small diameter, un-tethered implants cause the smallest tissue reactions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of nano MgO and BaSO4 particle size additives on properties of PMMA bone cement

A common technique to aid in implant fixation into surrounding bone is to inject bone cement into the space between the implant and surrounding bone. The most common bone cement material used clinically today is poly(methyl methacrylate), or PMMA. Although promising, there are numerous disadvantages of using PMMA in bone fixation applications which has limited its wide spread use. Specifically,...

متن کامل

نقش پوشش های بیوسرامیکی در موفقیت ایمپلنت ها

Characterization of bioceramics coating and evaluation of the influence of kind of coating on the implantation has been developed in recent years.Different bioceramics coating like calcium phosphate, hydroxyapatite, fluorapatite and bioglass were coated on dental and orthopedic implants. In-vitro and in-vivo experiments were done for evolution of implant success and reliability and study of fac...

متن کامل

How Much Bone Cement Is Utilized for Component Fixation in Primary Cemented Total Knee Arthroplasty?

Background: No scientific evidence exists regarding the amount of bone cement used and discarded in primarycemented Total knee arthroplasty (TKA). The aim of this study was to identify the exact amount of bone cement utilizedfor component fixation in primary TKA.Methods: In a prospective study carried out at five centers, 133 primary cemented TKAs were performed. One packof 40g Palacos bone cem...

متن کامل

Biologic Width around Dental Implants: An Updated Review

Soft tissue-implant interface is an important anatomical feature contributing to the long-term success of dental implants. Based on the available evidence, different factors may influence biological width around implants including the surgical technique, implant loading, implant surface properties, abutment materials, implant position, and width of the peri-implant mucosa. The purpose of the pr...

متن کامل

Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia

Background:  Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis  (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2011