Clinical significance of multiple systolic clicks from Starr-Edwards prosthetic aortic valves.
نویسندگان
چکیده
The use of echocardiography, phonocardiography, and spectroanalysis has enhanced the ability to detect prosthetic valve dysfunction even before the onset of symptoms in many patients. Reduction in the intensity of the opening and closing clicks and the appearance of new murmurs have been the most frequently reported observations in predicting prosthetic valve dysfunction. Simultaneous echocardiography, phonocardiography, and spectroanalysis were performed on 31 patients with Starr-Edwards prosthetic aortic valves. Eighteen patients had valves with metal (titanium or 'stellite') poppets, and 13 had valves with non-metal (silastic) poppets. In all patients with normally functioning valves with metal poppets, there were multiple systolic clicks on auscultation and confirmed by phonocardiography and spectroanalysis. In none of the patients with non-metal poppets were there clicks other than those associated with the normal opening and closing move-
منابع مشابه
Intravascular haemolysis after valve replacement: comparative study between Starr-Edwards (ball valve) and Björk-Shiley (disc valve) prosthesis.
Seventy-four patients with single prosthetic valves (Björk-Shiley or Starr-Edwards) in the mitral or aortic position and 18 controls with rheumatic valvar heart disease were investigated for evidence of intravascular haemolysis. Serum lactate dehydrogenase (LDH) was used as the most sensitive indicator of haemolysis. Raised concentrations were found in a third of 39 patients with Björk-Shiley p...
متن کاملHaemolysis with Björk-Shiley and Starr-Edwards prosthetic heart valves: a comparative study.
Slater, S. D., Saflam, I. A., Bain, W. H., Turner, M. A., and Lawrie, T. D. V. (1974). Thorax, 29, 624-632. Haemolysis with Bjork-Shiley and Starr-Edwards prosthetic heart valves: a comparative study. A comparison was made of the haemolytic complications in 85 patients with two different types of Starr-Edwards cloth-covered ball and cage prosthesis with those in 44 patients with the Bjork-Shile...
متن کاملExcellent durability of Starr-Edwards ball valves implanted in the aortic and mitral positions for 27 years: report of a rare surgical case.
A 59-year-old male who had undergone aortic and mitral valve replacement with Starr-Edwards ball valves 27 years ago was admitted to our hospital for hemolytic anemia and heart failure. Echocardiography revealed prosthetic valve failure with a high-pressure gradient and small effective orifice area. The Starr-Edwards ball valves were successfully replaced with bileaflet mechanical valves. The e...
متن کاملValve dysfunction of the cloth-covered Starr-Edwards ball valve.
BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...
متن کاملA novel method of assessing Starr-Edwards aortic valve stenosis.
C atheter assessment of Starr-Edwards prosthetic aortic valve stenosis requires simultaneous recording of left ventricular (LV) and aortic pressures. Passage of conventional Dacron catheters across mechanical valves can damage the mechanism and induce valvar incompetence. The alternative Bockenbrough procedure requires atrial septal puncture with potential lethal complications. The availability...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 39 6 شماره
صفحات -
تاریخ انتشار 1977