The various stress patterns of press-fit, ingrown, and cemented femoral stems.
نویسنده
چکیده
Finite-element analysis was used to study the general differences in load-transfer mechanisms and stress patterns of cemented, fully ingrown, proximally ingrown, and smooth press-fitted femoral stems in total hip arthroplasty (THA). Identical stems were used for the noncemented configurations and a similar stem shape for the cemented configurations. In each model, bone properties and loading characteristics were equal. Stem elastic moduli were varied so that the effects of cobalt-chromium-molybdenum (CoCrMo) and titanium as different stem materials could be assessed. The load-transfer mechanism is similar for all bonded configurations but differs dramatically for unbonded stems, e.g., press-fit designs. In the bonded configurations, interface stress concentrations occur on the proximal and distal sides. Stress value depends on stem rigidity, with higher proximal stress occurring in cemented stems and higher distal stress in noncemented stems. In the press-fit stem, the interface stresses are affected more by stem shape as a geometric entity and less by stem rigidity. Considering possible postoperative failure mechanisms, such as interface loosening and cortical bone loss, titanium is expected to produce better results in noncemented stems and CoCrMo in cemented stems. Cortical stress shielding as a qualitative phenomenon is caused by all stems, particularly in the calcar region. Quantitatively, stress-shielding effects differ with each type of fixation used. Stress-shielding effects are severe in fully ingrown stems and milder in cemented stems because of the differences in stem rigidity. The proximally ingrown stem falls between the fully ingrown and cemented stems in regard to stress shielding because stress transfer is more evenly distributed along the stem and concentrated at the lower coated edge. The press-fit stem provokes calcar stress shielding only. In the midstem region the stresses in the cortex are even greater than in the natural case.
منابع مشابه
The long-term results of press-fit cemented stems in total knee prostheses.
We evaluated the long-term fixation of 64 press-fit cemented stems of constrained total knee prostheses in 32 young patients with primary malignant bone tumours. Initial stable fixation, especially in rotation, was achieved by precise fit of the stem into the reamed endosteum, before cementation. Complementary fixation, especially in migration and rotation, was obtained by pressurised antibioti...
متن کاملEffects of fit and bonding characteristics of femoral stems on adaptive bone remodeling.
Bone atrophy caused by stress-shielding may cause serious complications for the long-term fixation of hip stems. In particular, uncemented total hip arthroplasty is threatened by this problem, because the stems are usually larger and, as a consequence, stiffer than those of cemented implants. In the present study, the effects of fit and bonding characteristics of femoral hip stems were investig...
متن کاملCemented stems are requisite in revision knee replacement.
Obtaining rigid prosthesis fixation in bone loss can be a significant challenge during revision total knee replacement (TKR).1 Stemmed prosthetic components off load stresses at the damaged metaphyseal interfaces, bypass bone defects, and provide additional prosthetic surface area for fixation.1-4 Relatively little longterm data exists documenting the durability of stemmed revision TKR and cont...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملPain at the end of the stem after revision total knee arthroplasty.
A consecutive series of patients undergoing revision total knee arthroplasty was studied prospectively. Clinical and radiographic assessment was performed preoperatively, 6 and 12 months postoperatively, and annually thereafter. Evaluation consisted of a Knee Society clinical score and assessment of patient satisfaction. In addition, patients completed drawings of their lower extremity regardin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 261 شماره
صفحات -
تاریخ انتشار 1990