Echocardiographic visualization of ventricular septal defect in infants and assessment of hemodynamic status using a contrast technique. Comparison of M-mode and two-dimensional imaging.

نویسندگان

  • T Funabashi
  • H Yoshida
  • S Nakaya
  • T Maeda
  • N Taniguchi
چکیده

Twenty-seven patients with ventricular septal defect (VSD), ages 2 months to 2 years, were evaluated by both M-mode and two-dimensional echocardiography (2-D echo) with the aid of a peripheral venous contrast technique. M-mode echocardiography was unreliable for imaging VSD. Using 2-D echo, defects in the interventricular septum were visualized in all patients examined; defects in the membranous portion (24 patients) were visualized by the subcostal frontal approach and defects in the supracristal portion (three patients) by the subcostal sagittal approach. The 2-D echo contrast study revealed negative contrast jets appearing through the defect in the right ventricle in 22 patients with a pulmonary-to-systemic blood flow ratio greater than 2.0, and positive contrast jets appearing through the defect in the left ventricle in 13 patients with a right-to-left ventricular peak pressure ratio greater than 0.71. We conclude that 2-D echo with peripheral contrast technique confirmed the anatomic location of VSD and indicated the approximate right-to-left ventricular peak pressure ratio, showing the contrast material shunting through the defect itself.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echocardiographic assessment of myocardial infarction: comparison of a rat model in two strains

The purpose of this study was to induce myocardial infarction (MI) and compare the echocardiographic parameters and mortality ratio of Lewis inbred and Wistar outbred strain before and after the procedure to help choose the best one for MI studies. In this study MI was induced in 46 Lewis and 34 Wistar by occlusion of left anterior descending artery (LAD). Doppler, two-dimensional (2-D) and 2-D...

متن کامل

Study of the Association between Congenital Heart Defects and Neuroblastoma in Abdominal Sonography

Abstract Background A higher prevalence of congenital heart defects (CHD) in neuroblastoma patients in general population is reported in some publications, however, some authors did not find such an association. The evidence for this relation comes from the observation that, the neural crest cells accompany to the development of the heart and neuroblastoma as well. Materials and Methods We...

متن کامل

Comparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method

Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...

متن کامل

بیماری‌های مادرزادی قلب در نوزادان مادران دیابتیک: یک بررسی اکوکاردیوگرافیک

Introduction: Despite the discovery of insulin and current improvement in diabetics care, congenital malformations in diabetics are still more frequent than in the general population. The aim of this study was to identify congenital heart dieases (CHD) in the newborns of diabetic mothers (IDMS). Methods: In our prospective study, color doppler echocardiography was performed in 75 consecutive f...

متن کامل

Prevalence and Etiology of Heart Murmurs in 2-24-Months-Old Infants Kerman, Iran

Background & aim: Congenital heart disease is one of the most common malformations at birth that require timely recognition and treatment. The aim of this study was to determine the prevalence and etiology of detected heart murmurs and association between congenital heart disease and heart murmurs. Recognition of murmurs etiology would help us to manage and treat them properly. Methods: In this...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 64 5  شماره 

صفحات  -

تاریخ انتشار 1981