Assessment of Body Composition Using Dual Energy X-Ray Absorptiometry in Patients with Liver Cirrhosis: Comparison with Anthropometry

نویسندگان

  • Seong Han Jeong
  • Jeong A Lee
  • Jin A Kim
  • Mun Woo Lee
  • Hee Bok Chae
  • Won Jun Choi
  • Hyoung Shik Shin
  • Ki Hyeong Lee
  • Sei Jin Youn
  • Sung Soo Koong
  • Seon Mee Park
چکیده

OBJECTIVES The aim of this study was to evaluate changes of body composition in cirrhotic patients. Dual energy x-ray absorptiometry (DEXA) and anthropometry were used, and the values obtained were compared. METHODS Mid-arm fat and muscle areas were calculated by anthropometry in 66 cirrhotic patients and 94 healthy controls. In 37 of the cirrhotic patients and 39 of the controls, fat mass, lean soft tissue mass and bone mineral contents were measured with DEXA. RESULTS The number of cirrhotic patients with measured values below the fifth percentile of normal controls was 21 (31.8%) by mid-arm fat area, six (9.1%) by mid-arm muscle area, 15 (40.5%) by fat mass and 0 (0%) by lean soft tissue mass. The fat mass in cirrhotic patients was less than in controls, whereas lean soft tissue mass and bone mineral content were not different. Fat depletion was severe in Child-class C patients and with severe ascites. Mid-arm fat area and fat mass showed close correlation (r = 0.85, p < 0.01), but mid-arm muscle area and lean soft tissue mass showed poor correlation (r = 0.32, p < 0.05). CONCLUSION Cirrhotic patients showed lower fat component, with preserved lean soft tissue mass and bone mineral content. In clinical practice, the measurement of mid-arm fat area was useful for the assessment of fat mass.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

Comparison between BMI and Inverted BMI in Evaluating Metabolic Risk and Body Composition in Iranian Children

Objectives: To compare BMI and inverted BMI in evaluating body measurement, resting blood pressure, Dual energy X-ray absorptiometry (DEXA) parameters of fat mass and metabolic risk factors in Iranian children Materials and Methods: This is a cross-sectional study on 477 children aged 9-18 yearsin the South of Iran. Weight, height, resting blood pressure, waist and hip circumference and puberta...

متن کامل

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Bedside methods versus dual energy X-ray absorptiometry for body composition measurement in COPD.

The measurement of body composition is of value in the nutritional assessment of patients with chronic obstructive pulmonary disease (COPD). The purpose of the present study was to compare two bedside methods for the measurement of body composition using dual energy X-ray absorptiometry (DEXA) as a reference method. Fat-free mass (FFM) was measured using DEXA, bioelectric impedance analysis (BI...

متن کامل

New percentage body fat prediction equations for Japanese females.

Anthropometry is a simple and cost-efficient method for the assessment of body composition. However prediction equations to estimate body composition using anthropometry should be 'population-specific'. Most popular body composition prediction equations for Japanese females were proposed more than 40 years ago and there is some concern regarding their usefulness in Japanese females living today...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 1999