Left Ventricular Wall Stress Calculated from One-Plane Cineangiography AN APPROACH TO FORCE-VELOCITY ANALYSIS IN MAN

نویسندگان

  • Herman L. Falsetti
  • Robert E. Mates
  • Colin Grant
  • David G. Greene
  • Ivan L. Bunnell
چکیده

Left ventricular dimensions from routine clinical one-plane cineangiograms were combined with left ventricular pressure measurements to permit calculation of left ventricular wall stresses. The 25 patients included 12 with normal left ventricular dynamics, 6 with volume overload, 3 with outflow obstruction, and 4 with cardiomyopathy. Average stresses calculated on the basis of an ellipsoid model agreed with average values obtained from the exact solution of a thick-walled elastic ellipsoidal shell. Peak values were 150 to 625 g/cm in the circular direction and 75 to 365 g/cm in the longitudinal direction. A fiber-corrected stress was defined which represents a force per muscle fiber. The variation in fiber-corrected stress during the cardiac cycle may be considerably different from the variation in simple stress. The force-velocity characteristics of circular fibers for the 25 patients are presented. The data on peak wall stress overlap in the four groups of patients. Peak velocity of circumferential fiber shortening varied from 0.44 to 0.63 lengths/sec in patients with myocardial weakness and varied from 0.74 to 2.56 lengths/sec in the other patients. Contractile element velocity was determined during ventricular ejection when the rate of force change equaled zero. Contractile element velocity of shortening was 0.22 to 0.32 lengths/sec in the cardiomyopathy group and 0.50 to 1.32 lengths/sec in the other patients. ADDITIONAL

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left ventricular wall stress calculated from one-plane cineangiography.

Left ventricular dimensions from routine clinical one-plane cineangiograms were combined with left ventricular pressure measurements to permit calculation of left ventricular wall stresses. The 25 patients included 12 with normal left ventricular dynamics, 6 with volume overload, 3 with outflow obstruction, and 4 with cardiomyopathy. Average stresses calculated on the basis of an ellipsoid mode...

متن کامل

Comparison of ultrasound and cineangiographic measurements of the mean rate of circumferential fiber shortening in man.

mean VCF by this noninvasive technic in patients studied by both methods. In 15 patients considered to have normal left ventricular function, the average mean VOF determined by ultrasound was 1.29 + 0.23 circumferences/sec, while in the 13 patients with reduced left ventricular performance this value was 0.75 + 0.16 circumferences/ sec (P < 0.001). Values of mean VCF by the two technics were si...

متن کامل

Comparison of directly measured left ventricular wall stress and stress calculated from geometric reference figures.

Mean left ventricular wall force was determined with a calibrated transmural auxotonic strain gauge in the left ventricle of six anesthetized, open-chest dogs with intact circulation. The gauge was oriented in the plane of the minor left ventricular equator, midway between the papillary muscles. Left ventricular internal volume was derived from the passive pressure-volume curve of the arrested ...

متن کامل

Mechanics of left ventricular contraction in chronic severe mitral regurgitation.

The mechanics of left ventricular contraction were studied during diagnostic cardiac catheterization using high-speed cineangiography in 11 patients with severe chronic mitral regurgitation. Compared with a group of previously studied normal subjects, most of the patients with mitral regurgitation demonstrated a reduced velocity of shortening (Vf) during ejection at maximum wall stress, average...

متن کامل

Performance evaluation of modified bentlegPlow using finite element approach

ABSTRACT-This paper aims to develop a new design of a bentleg (BL) plow and to determine its performance as compared to the conventional one using finite element approach. The difference between the modified and conventional BL plows is the direction of angle between the projection of cutting blade on horizontal plane normal to plow shank and the line perpendicular to the plow shank in the same...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005