Influence of ambient temperature on whole body and segmental bioimpedance spectroscopy measurements
نویسنده
چکیده
Bioimpedance spectroscopy (BIS) measurements are easy to implement and could be used for continuous monitoring. However, several factors (e.g. environment temperature) influence the measurements limiting the accuracy of the technology. Changes in skin temperature produced by changes in ambient temperature are related with changes in skin blood flow and skin impedance. It is assumed that skin impedance change is responsible for the error observed in whole body and segmental measurements. Measurements including body parts more distant from the torso seem to be more affected. In the present article skin and segment impedance have been performed on healthy subjects under extreme changes in environment temperature (13-39 °C). A commercial BIS device with a range between 5 kHz and 1 MHz has been used for the measurements. The results indicate that not only skin impedance, but also impedance of deeper tissue (e.g. muscle) may be responsible for the influence of environment temperature on BIS measurements. Segmental (knee-to-knee) BIS measurements show a relative change of only 2 %, while forearm and whole body impedance changed 14 % and 8 % respectively.
منابع مشابه
Influence of body position, food and beverage consumption on BIS measurements
Continuous monitoring of fluid changes using bioimpedance spectroscopy (BIS) during hemodialysis could help to predict hypotensive complications and extend the patient’s life. Food and beverage consumption during the treatment may influence the measurements and the calculated fluid removal. In the present article the change observed in whole body and segmental (knee-to-knee, abdomen) BIS measur...
متن کاملSegmental Spectral Decomposition as a Time Persistent Method of BioImpedance Spectroscopy Feature Extraction
BioImpedance Spectroscopy (BIS) have been investigated in many research areas as a method to detect changes in living tissues. However, BIS measurements are known to be hardly reproducible in clinical applications. This article proposes segmental spectral decomposition as a method of extracting reproducible parameters from raw BIS. The efficiency of this method is then compared to conventional ...
متن کاملSegment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients.
Discrepancies in body fluid estimates between segmental bioimpedance spectroscopy (SBIS) and gold-standard methods may be due to the use of a uniform value of tissue resistivity to compute extracellular fluid volume (ECV) and intracellular fluid volume (ICV). Discrepancies may also arise from the exclusion of fluid volumes of hands, feet, neck, and head from measurements due to electrode positi...
متن کاملDynamics of segmental extracellular volumes during changes in body position by bioimpedance analysis.
Extracellular volume (ECV) of arms, trunk, and legs determined from segmental bioimpedance data in 11 healthy men (31.6 +/- 7 yr) obtained at the end of a 30-min equilibration phase in the supine body position was compared with ECV determined from whole body measurements (ECVWB). ECV was calculated from extracellular resistance (RECV) identified from the bioimpedance spectrum for a range of 10 ...
متن کاملEffect of change in fluid distribution in segments in hemodialysis patients at different ultrafiltration rates on accuracy of whole body bioimpedance measurement.
This study explored divergence (error) between ultrafiltration volumes (UFV) and intradialytic changes in extracellular volume (ΔECV) in hemodialysis (HD) patients measured by whole body (wBIS) and sum of segmental bioimpedance spectroscopy (sBIS). The primary aim of the study was to evaluate the effect of different ultrafiltration rates (UFR) on error of estimation of ΔECV by changes in their ...
متن کامل