External quality assessment in clinical cell analysis by flow cytometry. Why is it so important?

نویسندگان

  • Zoran Siftar
  • Mirjana Mariana Kardum Paro
  • Ivica Sokolić
  • Aida Nazor
  • Zlata Flegar Mestrić
چکیده

Participation in external quality assessment is an integral part of laboratory work and mandatory when the results have a clinical application, which is one of the requirements of standard 15189 for accreditation of medical laboratories. Institute of Clinical Chemistry, the first laboratory accredited for clinical cell analysis by flow cytometry in Croatia, participated in UKNEQAS for Leukocyte Immunophenotyping in 3 schemes: "Immune Monitoring", "CD34 Stem Cell Enumeration" and "Leukaemia Immunophenotyping". For sample processing on EPICS XL flow cytometer, lyse/no wash preparation technique with ammonium chloride (NH4Cl) or ImmunoPrep lysing reagent was employed. In "Immune monitoring" programme CD45/sideward light scatter (SSC) proposed gating strategy was adopted for lymphocyte subsets, while modified ISHAGE protocol was used for CD34+ cell enumeration. Absolute count determination was performed on flow cytometer using FlowCount beads solution. In the period from the beginning of 2006 until the middle of 2009 a total number of 100 stabilized whole blood samples were processed. The relative and absolute enumeration results for lymphocyte subsets were within tolerable limits, in 97.1 and 97.1% of cases, and 95 and 90% of CD34+ cell enumeration, respectively. In immune monitoring CD45/SSC proposed gating strategy is the most frequent analysis used (> 85% participants) and ISHAGE protocol for CD34+ cell determination with continuous rise from 76 to 83%. A number of participants who accept beads method for absolute count enumeration on flow cytometer get greater, 69 to 86%, while FlowCount was the second of bead-based techniques used (25 and 35%). Sample treatment in lyse/no wash technique using NH4Cl lysing solution was dominant procedure used by more than 1/3 participants, although its home made solution has replaced slowly by commercial reagents. The unacceptable results, 6 of 244, were obtained for 20 most frequently determined cell antigens in "Leukaemia Immunophenotyping" samples screened for leukaemia/lymphoma. Processing results of all participants showed that the deviation from laboratory guidelines and the use of older methods for cell identification, quantification of cell counting on haematology analyser, or usage an antibody conjugated with fluorochrome lesser fluorescence quantum often lead to an unacceptable result, although is noticeable trend to accept new referrals and protocols to reduce the inter-laboratory differences.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow Cytometry: A New Approach for Indirect Assessment of Sperm Protamine Deficiency

Background Flow cytometry (FCM) has been extensively used to study mammalian sperm in the areas of clinical andrology and reproductive toxicology. FCM provides a powerful advantage over microscopy technique in terms of rapid accurate and reproducible technology for the quantification of various cell characteristics including chromatin status. During spermiogenesis histones are replaced by prota...

متن کامل

Optimized Method for Reticulocyte Counting: Simple, Accurate, and Comparable to Flow Cytometry

Background: Reticulocytes are immature red blood cells with RNA, spending the final stages of their maturation in the peripheral blood. The number of reticulocytes in the peripheral blood is the salient evidence of the effectiveness of bone marrow to produce red blood cells. Currently, reticulocyte count is done manually or automatically in clinical laboratories. Difficulties and limitations of...

متن کامل

روش‌های بررسی آپوپتوز

Background and Objective: Apoptosis or programmed cell death is an important process for cellular homeostasis and it can be initiated by both physiologic and pathologic stimuli. Defects in the apoptosis process may lead to serious disease such as autoimmune diseases, cancer, tumors drug resistance, and the acquired immunodeficiency syndrome (AIDS). Various methods such as cytotoxicity assay, mo...

متن کامل

P-52: Interest of Measuring MitochondrialMembrane Potential of Sperm by Flow Cytometry Technique in The Exploration ofSperm Quality of Infertile Men

Background: The fertilizing sperm potential is directly related to its mitochondria activity evaluated by measuring the mitochondrial membrane potential (ΔΨm). The objectives of the present study were to investigate the vitality and mitochondrial membrane potential of sperm in infertile men by the and to assess the correlations between sperm parameters and the level of sperm mitochondrial membr...

متن کامل

P-6: Flow Cytometry: Assessment of Protamine Deficiency by CMA3 Staining and Apoptotic Bodies

Background: Chromomycin A3 (CMA3) staining, with the slide method or fluorescence microscopy, is widely used for indirect assessment of protamine deficiency in a semen sample. Flow cytometry is the most suitable tool which to improve assessment accuracy, both in terms of statistical analysis and to prevent observer variation. This study provides a simple procedure to account for merocyanine 540...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Collegium antropologicum

دوره 34 1  شماره 

صفحات  -

تاریخ انتشار 2010