ASPECTS (Alberta Stroke Program Early CT Score) Assessment of the Perfusion-Diffusion Mismatch.

نویسندگان

  • Louis Lassalle
  • Guillaume Turc
  • Marie Tisserand
  • Sylvain Charron
  • Pauline Roca
  • Stephanie Lion
  • Laurence Legrand
  • Myriam Edjlali
  • Olivier Naggara
  • Jean-François Meder
  • Jean-Louis Mas
  • Jean-Claude Baron
  • Catherine Oppenheim
چکیده

BACKGROUND AND PURPOSE Rapid and reliable assessment of the perfusion-weighted imaging (PWI)/diffusion-weighted imaging (DWI) mismatch is required to promote its wider application in both acute stroke clinical routine and trials. We tested whether an evaluation based on the Alberta Stroke Program Early CT Score (ASPECTS) reliably identifies the PWI/DWI mismatch. METHODS A total of 232 consecutive patients with acute middle cerebral artery stroke who underwent pretreatment magnetic resonance imaging (PWI and DWI) were retrospectively evaluated. PWI-ASPECTS and DWI-ASPECTS were determined blind from manually segmented PWI and DWI volumes. Mismatch-ASPECTS was defined as the difference between PWI-ASPECTS and DWI-ASPECTS (a high score indicates a large mismatch). We determined the mismatch-ASPECTS cutoff that best identified the volumetric mismatch, defined as VolumeTmax>6s/VolumeDWI≥1.8, a volume difference≥15 mL, and a VolumeDWI<70 mL. RESULTS Inter-reader agreement was almost perfect for PWI-ASPECTS (κ=0.95 [95% confidence interval, 0.90-1]), and DWI-ASPECTS (κ=0.96 [95% confidence interval, 0.91-1]). There were strong negative correlations between volumetric and ASPECTS-based assessments of DWI lesions (ρ=-0.84, P<0.01) and PWI lesions (ρ=-0.90, P<0.01). Receiver operating characteristic curve analysis showed that a mismatch-ASPECTS ≥2 best identified a volumetric mismatch, with a sensitivity of 0.93 (95% confidence interval, 0.89-0.98) and a specificity of 0.82 (95% confidence interval, 0.74-0.89). CONCLUSIONS The mismatch-ASPECTS method can detect a true mismatch in patients with acute middle cerebral artery stroke. It could be used for rapid screening of patients with eligible mismatch, in centers not equipped with ultrafast postprocessing software.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CT-NIHSS mismatch does not correlate with MRI diffusion-perfusion mismatch.

BACKGROUND AND PURPOSE MRI diffusion-perfusion mismatch may identify patients for thrombolysis beyond 3 hours. However, MRI has limited availability in many hospitals. We investigated whether mismatch between the Alberta Stroke Program Early CT Score (ASPECTS) and the NIH Stroke Scale (NIHSS) correlates with MRI diffusion-perfusion mismatch. METHODS We retrospectively analyzed a cohort of con...

متن کامل

Computed Tomography Perfusion Alberta Stroke Program Early Computed Tomography Score Is Associated with Hemorrhagic Transformation after Acute Cardioembolic Stroke

Alberta Stroke Program Early Computed Tomography (CT) score (ASPECTS) has been applied to CT perfusion (CTP) with good interrater agreement to predict early ischemic stroke, and it can be useful in decision making in acute ischemic stroke. The aim of the present study was to assess the predictive value of CTP ASPECTS of hemorrhagic transformation (HT) in acute cardioembolic stroke. This is a si...

متن کامل

A Critical Review of Alberta Stroke Program Early CT Score for Evaluation of Acute Stroke Imaging

Assessment of ischemic stroke lesions on computed tomography (CT) or MRI using the Alberta Stroke Program Early CT Score (ASPECTS) is widely used to guide acute stroke treatment. We aimed to review the current evidence on ASPECTS. Originally, the score was developed for standardized lesion assessment on non-contrast CT (NCCT). Early studies described ASPECTS as a predictor of functional outcome...

متن کامل

Rapid assessment of perfusion-diffusion mismatch.

BACKGROUND AND PURPOSE For MR perfusion-diffusion (PWI-DWI) mismatch to become routine in thrombolysis patient selection, rapid and reliable assessment tools are required. We examined interrater variability in PWI/DWI volume measurements and developed a rapid assessment tool based on the Alberta Stroke Program Early CT Scores (ASPECTS) system. METHODS DWI and PWI were performed in 35 patients...

متن کامل

Accuracy of the Alberta Stroke Program Early CT Score during the first 3 hours of middle cerebral artery stroke: comparison of noncontrast CT, CT angiography source images, and CT perfusion.

BACKGROUND AND PURPOSE The Alberta Stroke Program Early CT Score (ASPECTS) is a reliable method of delineating the extent of middle cerebral artery (MCA) stroke. Our aim was to retrospectively compare the accuracy of ASPECTS on noncontrast CT, CT angiography (CTA) source images, and CT perfusion maps of cerebral blood volume (CBV) during the first 3 hours of middle cerebral artery (MCA) stroke....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 47 10  شماره 

صفحات  -

تاریخ انتشار 2016