Cardiac magnetic resonance assessed valve morphology and aortic distensibility in severe aortic stenosis
نویسندگان
چکیده
Methods 46 patients with severe AS without obstructive coronary artery disease awaiting aortic valve replacement were studied. Transthoracic echocardiography (TTE) was used to assess aortic valve area using the continuity equation, peak aortic velocity and mean valve gradient. CMR was used to assess aortic valve morphology and to enable planimetry of aortic valve area. Two SSFP cines of the aortic valve were taken; one planned from a 3chamber cine at the level of the aortic annulus in enddiastole and one at the aortic valve tips in end-systole. The smallest planimetered valve area was used for analysis. A high temporal resolution cine of the ascending aorta was taken at the level of the pulmonary artery bifurcation with three blood pressure recordings taken at the same time; the average of the three readings was used for analysis. AD was calculated according to the formula (aortic area max aortic area min/ aortic area max)*(systolic BP diastolic BP). Results Baseline characteristics; Males 74%, CMR aortic valve area 0.76±0.21 cm2 TTE aortic valve area 0.86±0.22 cm2, peak velocity 4.4±0.6m/s and mean gradient 48.5 ±14.1mmHg. AD was not normally distributed therefore was log transformed before analysis. The valve morphology could be clearly seen in all patients. More than half of the patients (63%) studied had bicuspid aortic valves, see Table 1. The bicuspid valves were classified as either Type 1 (fusion of right and left coronary cusps), Type 2 (fusion of right and non-coronary cusps), or Type 3 (fusion of left and non-coronary cusps). Of the 22 bicuspid valves with a raphe 14 were Type 1, eight Type 2 and no Type 3, of the seven without a raphe five were Type 1, two Type 2 and no Type 3. Valve morphology did not significantly correlate with valve area (TTE or CMR) or velocities/gradients. AD was not correlated with sex, age, aortic valve areas (CMR or TTE) or velocities/gradients. AD significantly decreased from trileaflet to bicuspid valve with raphe present and then further to bicuspid valve with raphe absent (ANOVA p=0.01), Figure 1.
منابع مشابه
Assessment of aortic stiffness by cardiovascular magnetic resonance following the treatment of severe aortic stenosis by TAVI and surgical AVR
BACKGROUND Aortic stiffness is increasingly used as an independent predictor of adverse cardiovascular outcomes. We sought to compare the impact of transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) upon aortic vascular function using cardiovascular magnetic resonance (CMR) measurements of aortic distensibility and pulse wave velocity (PWV). METHODS AN...
متن کاملQuadriscupid Aortic Valve with Concurrent Aortic Stenosis and Insufficiency
We present the case of a 22-year-old man with a congenital mixed aortic valve dysfunction who underwent cardiac Magnetic Resonance Imaging (MRI) for the assessment of aortic valve morphology and function prior to valve replacement. Cardiac MRI showed a four-leaf-clover aortic valve morphology, the typical presentation of a quadricuspid aortic valve. The patient underwent a successful Bentall pr...
متن کاملSignificance of myocardial fibrosis on cardiac function and morphology in severe aortic stenosis
Methods Eighty-nine patients (53 male, mean age 60 years) with pure severe AS (n = 36) or severe AS with mild aortic regurgitation (n = 53) were included in the study. All patients underwent transthoracic echocardiography (TTE), cardiac computed tomography (CCT) and cardiac magnetic resonance (CMR) and subsequent valvuloplasty operation. Patients were analyzed according to the presence and abse...
متن کاملLeft ventricular remodelling and hypertrophy in patients with aortic stenosis: insights from cardiac magnetic resonance imaging
Methods Consecutive patients with moderate or severe AS (aortic valve area <1.5cm), normal coronary arteries and no other significant valve lesion or cardiomyopathy were scanned by 1.5T magnetic resonance and compared with contemporary ageand sex-matched healthy, control subjects. The extent and patterns of hypertrophy were assessed from volumetric cine images. Valve severity was assessed by pl...
متن کاملComparison of magnetic resonance imaging and cardiac catheterization in patients with suspected severe aortic stenosis.
OBJECTIVE Magnetic resonance imaging (MRI) is a novel technique used in the assessment of aortic stenosis. The aim of the study was to compare MRI and cardiac catheterization (CAT) that is still considered to be a "golden standard" in this indication. METHODS Thirty-four patients referred to CAT for the evaluation of aortic stenosis were enrolled into the study. CAT was performed according to...
متن کامل