Evaluation of the accuracy of Cone Beam Computerized Tomography (CBCT): medical imaging technology in head and neck reconstruction
نویسندگان
چکیده
BACKGROUND With the introduction, development and commercialization of Cone Beam Computerized Tomography (CBCT) technologies in the field of head and neck reconstruction, clinicians now have increased access to the technology. Given the growth of this new user group, there is an increasing concern regarding proper use, understanding, quality and patient safety. METHODS The present study was carried out to evaluate data acquisition of CBCT medical imaging technology and the accuracy of the scanning at three different machine warming times. The study also compared the accuracy of CBCT at 0.2 mm slice thickness and Computerized Tomography (CT) at 1 mm slice thickness. A control model was CT scanned at five random intervals, at 1 mm slice thickness and CBCT scanned at specialized intervals, at 0.2 mm slice thickness. The data was then converted and imported into a software program where a digital registration procedure was used to compare the average deviations of the scanned models to the control. RESULTS The study found that there was no statistically significant difference amongst the three CBCT machine warming times. There was a statistically significant difference between CT scanning with 1 mm slice thickness and CBCT scanning with 0.2 mm slice thickness. CONCLUSIONS The accuracy of the i-CAT CBCT scans used in the present study with a parameter at voxel size 0.2, will remain consistent and reliable at any warming stage. Also the difference between the CBCT i-CAT scans and the CT scans was not clinically significant based on suggested requirements of clinicians in head and neck reconstruction.
منابع مشابه
Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality
Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...
متن کاملThe Accuracy of Cone-beam Computerized Tomography Linear Measurements in Human Dry Mandible
Background & Aims: The aim of this study was to evaluate the accuracy of Cone-beam Computerized Tomography (CBCT) linear measurements in dry mandibles by comparing them with direct measurements. Methods: Two human dry mandibles were used in this study. Thirteen sites were selected on each mandible. Specimens were scanned by CBCT and linear measurements were made using Planmeca Romexis 2.3.0.R s...
متن کاملEvaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners
Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...
متن کاملEffect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...
متن کاملComparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications
Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...
متن کامل