Purification of fibrinogen and the separation of its degradation products in the presence of calcium ions [proceedings].
نویسندگان
چکیده
Gaskin, F., Cantor, C. R. & Shelanski, M. L. (1975) Ann. N. Y . Acod. Sci. 253, 133-146 Lowry, 0. H., Rosebrough, N. J., Farr, A. L. & Randall. R. J. (1951)J. Biol. Chem. 193,265-275 Maddy, A. H. & Spooner, R. 0. (1970) Vos Song. 18,34-41 Shapiro, A. L., Vinuela, E. & Maizel, J. V. (1967) Biochem. Biophvs. Res. Cornmitn. 28, 815-820 Strzinek, R. A,, Vela, G . R., Scholes, V. E. & Norton, S . J. (1970) Cancer Res. 30, 334-337 Thomas, J. 0. (1974) in Componioii / o Biochemistry ( B u l l , A. T . , Lagnado, J. R., Thomas, J. 0.
منابع مشابه
A Biotechnological Perspective on The Affinity Magnetic Separation and Purification Based on Oligonucleotides
The rapidly growing field of biotechnology has created a critical need for simple, fast andhigh-throughput processes for the separation and purification of biomolecules from biologicalmatrices. In recent years, several bioseparation techniques have been proposed as advancedalternatives to the classical separation methods. These modern processes emphasize ultrahighselective and sensitive analysi...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSTUDY ON THE COMPLEX FORMATION BETWEEN N-PROPYLSALICYLIDENE BASED ON SILICA AS ION EXCHANGER AND SOME TRANSITION METAL IONS
N-propylsalicylidene based on silica as ion exchanger (IE) was used for the separation by complexation of Mn2+, Co2+, Ni2+, Cu2+, Hg2+, Cr3+, Fe3+, and UO22+ from their parent solutions. IE and its metal complexes are characterized by elemental analysis, electronic and infrared spectra, in addition to thermal analysis in atmospheric pressure. The mode of chelation and the proposed geometric str...
متن کاملImproved Extraction-Separation of Lanthanum/ Europium Ions by Bis(2-ethylhexyl)phosphoric Acid Using 12-Crown-4 as an Ion Selective Masking Agent
The extraction-separation of lanthanum and europium ions with bis(2-ethylhexyl) phosphoric acid (DEHPA) in cyclohexane was improved by adding 12-crown-4 (12C4) to the aqueous phase as a masking agent. In the presence of this crown ether the extraction curve of lanthanum ions versus pH shifts to the higher pH region, while the curve is not influenced for the europium ions. Consequently the s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biochemical Society transactions
دوره 7 4 شماره
صفحات -
تاریخ انتشار 1979