Water Calorimetry: A Correction to the Heat Defect Calculations

نویسندگان

  • Norman V. Klassen
  • Carl K. Ross
چکیده

In a recent publication, we used a reaction model (model III) to calculate the heat defect for the irradiation of aqueous solutions with ionizing radiation at 21 °C. Subsequent work has revealed that the literature value used for one of the rate constants in the model was incorrect. A revised model (model IIIR) incorporates the correct rate constant for 21 °C. Versions of models III and IIIR were created for irradiations at 4 °C. For our current water calorimetry protocol, the values of the heat defect for H2/O2-water (water saturated with a flow of 43 % H2 and 57 % O2, by volume) at 21 °C predicted by model III and model IIIR are similar but the value for 4 °C predicted by III is 30 % smaller than the value predicted by IIIR. Model IIIR predicts that the values of the heat defect at 21 °C and 4 °C lie within the range -0.023±0.002, in agreement with the values obtained from our water calorimetry measurements done using pure water and H2-saturated water at 21 °C and 4 °C. The yields of hydrogen peroxide in H2/O2-water at 21 °C and 4 °C were measured and agree with the predictions of model IIIR. Our water calorimetry measurements made with pure water and H2-saturated water are now of sufficient quality that they can be used to determine the heat defect for H2/O2-water better than can be done by simulations. However, consistency between the three systems continues to be an excellent check on water purity which is crucial, especially for the pure water system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement and comparison of the temperature-dependence of refractive index of water and Plexiglas phantoms by interferometry method for their use in optical calorimetry

In radiation calorimetry by using laser beams and interferometry setups, variations induced by dose absorption in phantom can be precisely measured. Dose absorption and the induced temperature change result in refractive index variation of the material. In order to be able to measure the low amount of absorbed dose in the phantom, temperature dependence of refractive index of the material must ...

متن کامل

Convection Heat Transfer Modeling of Nano- fluid Tio2 Using Different Viscosity Theories

In this paper, the effects of adding nanoparticles including Tio2 to a fluid media for purpose of free convection heat transfer improvement were analyzed. The free convection was assumed to be in laminar flow regime and the solutions and calculations were all done by the integral method. Water, as a Newtonian fluid, was considered the base fluid (water) and all the thermo physical properties of...

متن کامل

Calorimetry for Absorbed-dose Measurements at BNM-LNHB

At BNM-LNHB, the references in terms of absorbed dose to water are based on graphite calorimeter measurements. In the cobalt-60 beam, measurements were performed directly with the graphite calorimeter in a graphite phantom. Absorbed dose to water in a water phantom was then determined using a transfer method by means of relative measurements made with ionisation chambers and Fricke dosimeters. ...

متن کامل

Water Calorimetry: The Heat Defect

Domen developed a sealed water calorimeter at NIST to measure absorbed dose to water from ionizing radiation. This calorimeter exhibited anomalous behavior using water saturated with gas mixtures of H2 and O2. Using computer simulations of the radiolysis of water, we show that the observed behavior can be explained if, in the gas mixtures, the amount-of-substance of H2 and of O2 differed signif...

متن کامل

A human calorimeter for the direct and indirect measurement of 24 h energy expenditure.

1. A calorimeter for the continuous measurement of heat production and heat loss in the human subject, for at least 24 h, is described. The calorimeter operated on the heat-sink principle for direct calorimetry and an open-circuit system for indirect calorimetry. 2. Sensible heat loss was measured using a water-cooled heat exchanger, and the temperature of water entering the heat exchanger was ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 107  شماره 

صفحات  -

تاریخ انتشار 2002