Multisite Laboratory Evaluation of a Dual Human Immunodeficiency Virus (HIV)/Syphilis Point-of-Care Rapid Test for Simultaneous Detection of HIV and Syphilis Infection
نویسندگان
چکیده
BACKGROUND Recently, test developers have created rapid point-of-care tests that can simultaneously detect multiple infections within the same specimen using a single device. The SD BIOLINE Duo HIV/Syphilis rapid point-of-care test uses a solid-phase immunochromatographic assay to detect immunoglobulin (Ig)G, IgM, and IgA antibodies to human immunodeficiency virus (HIV)-specific antigens (HIV-1 gp41, sub O, HIV-2 gp36) and recombinant Treponema pallidum antigen (17 kDa) in human serum. This study was a multisite laboratory-based evaluation of the performance of SD BIOLINE HIV/Syphilis Duo test using previously characterized sera in 6 countries. METHODS Laboratories in Ghana, Mexico, Laos, Togo, Kenya, and Myanmar participated in the evaluation during 2012-2013. Each site characterized sera using T pallidum particle agglutination assay or T pallidum hemagglutination assay and HIV enzyme immunoassay, Western blot, and/or HIV antibody rapid tests. Those gold standard test results were compared with SD BIOLINE Duo test results. We calculated the sensitivity and specificity of test performance and used the exact binomial method to calculate 95% confidence intervals (CIs). RESULTS The sensitivity and specificity for the HIV antibody test component (n = 2336) were estimated at 99.91% (95% CI, 99.51% and 100%) and 99.67% (95% CI, 99.16% and 99.91%), respectively. For the T pallidum test component (n = 2059), the sensitivity and specificity were estimated at 99.67% (95% CI, 98.82% and 99.96%) and 99.72% (95% CI, 99.29% and 99.92%), respectively. CONCLUSIONS The sensitivity and specificity of the SD BIOLINE HIV/Syphilis Duo test were consistently high across sera specimens from 6 countries around the world. Dual rapid tests should be considered for improved HIV and syphilis screening coverage.
منابع مشابه
Laboratory Evaluation of a Point-of-Care Downward-Flow Assay for Simultaneous Detection of Antibodies to Treponema pallidum and Human Immunodeficiency Virus.
Combining the detection of syphilis and HIV antibodies into one point-of-care test integrates syphilis screening into already existing HIV screening programs, which may be particularly beneficial in settings such as antenatal care. Using the INSTI Multiplex downward-flow immunoassay, we tested 200 stored serum samples from high-risk patients enrolled in a longitudinal study on HIV infection and...
متن کاملEvaluation of the Seroprevalence of Transfusion Transmissible Infections among Blood Donors in a Tertiary Care Hospital of North India
Background: Unsafe transfusion practices put patients at high risk of transfusion transmissible infections. We aimed to evaluate the prevalence of transfusion transmissible infections (including Human Immunodeficiency Virus [HIV] 1 and 2, Hepatitis B Virus [HBV], Hepatitis C Virus (HCV) and syphilis) during a period of 18 months among blood donors in the Blood Bank of Lady Hardinge Medical Coll...
متن کاملPrevalence of HAV Ab, HEV (IgG), HSV2 IgG, and Syphilis Among Sheltered Homeless Adults in Tehran, 2012
Background This study investigated the prevalence for hepatitis A virus (HAV), hepatitis E virus (HEV), herpes simplex virus type 2 (HSV2) and syphilis among homeless in the city of Tehran. Methods In this cross-sectional study, 596 homeless were recruited in Tehran. A researcher-designed questionnaire was used to study demographic data. Using enzyme-linked immunoassay, and rapid plasma reagi...
متن کاملA Simple and Rapid Method for the Detection of HIV-1/HCV in Co-Infected Patients
Background: Due to some limitations of serological methods in diagnosis of patients infected with HIV-1 (human immunodeficiency virus) and HCV (hepatitis C virus), it is profoundly important to use molecular methods for the detecting of these infectious agents. However, the most significant problems are the exorbitant cost of these methods and the need of a thermocycler which is an expensive...
متن کاملLaboratory evaluation of the Chembio Dual Path Platform HIV-Syphilis Assay
BACKGROUND Use of rapid diagnostic tests for HIV and syphilis has increased remarkably in the last decade. As new rapid diagnostic tests become available, there is a continuous need to assess their performance and operational characteristics prior to use in clinical settings. OBJECTIVES In this study, we evaluated the performance of the Chembio Dual Path Platform (DPP®) HIV-Syphilis Assay to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 1 شماره
صفحات -
تاریخ انتشار 2014