Capillary-valve-based fabrication of ion-selective membrane junction for electrokinetic sample preconcentration in PDMS chip.

نویسندگان

  • Vincent Liu
  • Yong-Ak Song
  • Jongyoon Han
چکیده

In this paper, we report a novel method for fabricating ion-selective membranes in poly(dimethylsiloxane) (PDMS)/glass-based microfluidic preconcentrators. Based on the concept of capillary valves, this fabrication method involves filling a lithographically patterned junction between two microchannels with an ion-selective material such as Nafion resin; subsequent curing results in a high aspect-ratio membrane for use in electrokinetic sample preconcentration. To demonstrate the concentration performance of this high-aspect-ratio, ion-selective membrane, we integrated the preconcentrator with a surface-based immunoassay for R-Phycoerythrin (RPE). Using a 1x PBS buffer system, the preconcentrator-enhanced immunoassay showed an approximately 100x improvement in sensitivity within 30 min. This is the first time that an electrokinetic microfluidic preconcentrator based on ion concentration polarization (ICP) has been used in high ionic strength buffer solutions to enhance the sensitivity of a surface-based immunoassay.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pneumatic Microvalve for Electrokinetic Sample Preconcentration and Capillary Electrophoresis Injection

Here we show that a closed pneumatic microvalve on a PDMS chip can serve as a semipermeable membrane under an applied potential, enabling current to pass through while blocking the passage of charged analytes. Enrichment of both anionic and cationic species has been demonstrated, and concentration factors of ~70 have been achieved in just 8 s. Once analytes are concentrated, the valve is briefl...

متن کامل

Creating sub-50 nm nanofluidic junctions in a PDMS microchip via self-assembly process of colloidal silica beads for electrokinetic concentration of biomolecules.

In this work we describe a novel and simple self-assembly process of colloidal silica beads to create a nanofluidic junction between two microchannels. The nanoporous membrane was used to induce ion concentration polarization inside the microchannel and this electrokinetic preconcentration system allowed rapid concentration of DNA samples by ~1700 times and of protein samples by ~100 times with...

متن کامل

Novel Non-equilibrium Electrokinetic Micromixer with Nanoporous Membrane Fabricated by Laser Polymerization Technique

We propose a non-equilibrium electrokinetic (EK) mixer with a nanoporous membrane fabricated on a microfluidic chip by laser polymerization technique. A non-equilibrium EK mixer had an array of nanochannels to generate a vortex using ion depletion and consequent electroconvection [1]. The nanochannels, however, require expensive and complicated fabrication processes. On the other hand, the lase...

متن کامل

Real-time dual-loop electric current measurement for label-free nanofluidic preconcentration chip.

An electrokinetic trapping (EKT)-based nanofluidic preconcentration device with the capability of label-free monitoring trapped biomolecules through real-time dual-loop electric current measurement was demonstrated. Universal current-voltage (I-V) curves of EKT-based preconcentration devices, consisting of two microchannels connected by ion-selective channels, are presented for functional valid...

متن کامل

Nanofluidic preconcentration device in a straight microchannel using ion concentration polarization.

In this paper, we introduce a simple, straight microchannel design for a nanofluidic protein concentration device. Compared with concentration devices previously developed, the anode channel and cathode channel in this new concentration scheme are both integrated into a straight microchannel, with one inlet and one outlet. Most of the functions of a conventional two-channel concentration device...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 10 11  شماره 

صفحات  -

تاریخ انتشار 2010