Microbiological assessment of the implant-abutment interface in different connections: cross-sectional study after 5 years of functional loading.

نویسندگان

  • Luigi Canullo
  • David Penarrocha-Oltra
  • Claudio Soldini
  • Fabio Mazzocco
  • Maria Penarrocha
  • Ugo Covani
چکیده

OBJECTIVE To evaluate the bacterial microflora present inside the implant connection and in the peri-implant sulcus fluid of healthy implants, and to analyze the relationships between these harboring sites for four different implant systems after at least 5 years of functional loading. MATERIALS AND METHODS A cross-sectional study was performed involving 40 patients treated with metal-ceramic cemented bridges supported by at least two healthy implants functionally loaded for 5 years. Four different implant-abutment connections were studied: external hexagon (control group), double internal hexagon (test group 1), internal hexagon with external collar (test group 2), and conical connection (test group 3). Samples for microbiological analysis were obtained from three types of sites: peri-implant sulci, connections' inside and abutments surface and, as control, gingival sulci of neighboring teeth. Quantitative real-time PCR was carried out for Total Bacterial Count and for 10 microorganisms: Aggregatibacter actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythensis, Treponema denticola, Prevotella intermedia, Peptostreptococcus micros, Fusobacterium nucleatum, Campylobacter rectus, Eikenella corrodens, and Candida albicans. The response variables were percentage of positive sites and absolute bacterial load. The relations of the response variables with the type of connection and of sampling site were assessed using generalized estimating equations. RESULTS Regarding the analysis of positivity to bacteria in the peri-implant sulcus no significant differences were observed. Analyzing the connection's inside, none of the connection designs had the capacity to prevent microbiological leakage through the implant/abutment microgap. Test group 3 presented the lowest mean values for red complex bacteria and control group the highest, although differences were non-significant. Statistical significance was only reached for Treponema denticola in the bacterial load analysis inside the connection. Test groups 1 and 2 yielded lower values for orange complex bacteria but only for Peptostreptococos micros the differences resulted significant. Test groups 2 and 3 had significantly lower total bacterial counts in the peri-implant sulcus and inside the connection. CONCLUSIONS Outcomes suggested that all the analyzed connections resulted contaminated after 5 years of functional loading. However, the connection design might influence bacterial activity levels qualitatively and quantitatively, especially inside the implant connection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Evaluation of Microgap at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract   Background and Aim : Microgap in the implant-abutment interface is one of the main challenges in the treatment of two-piece implants. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microgap at implant-abutment interface area under oblique cyclic loading in vitro. Methods and Materials In this in vitro study, 12 implant-abutment assemb...

متن کامل

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

Evaluation of the Effect of Zirconia and Titanium Abutments on Microleakage of Implant-Abutment Interface Under Oblique Cyclic Loading In Vitro

Background and Aim: Oral bacteria can proliferate in the implant-abutment interface (IAI) and cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to assess the effect of zirconia and titanium abutments on the microleakage of the IAI under oblique cyclic loading conditions. Materials and Methods: In this in-vitro study, 12 implant-abutment assemblies with zirconia...

متن کامل

Effect of GapSeal® as a Sealing Material on Microgap and Microleakage at External Hexagon Implant Connections Following Cyclic Loading: An In Vitro Study

Background and Aim: The mismatch of the implant-abutment connection can produce instant stress and microleakage which result in mechanical and biological complications. This study aimed to investigate the influence of GapSeal® as a sealing material on the extent of microgap and microleakage at the external hexagon implant platform following cyclic loading. Materials and Methods: Sixteen implan...

متن کامل

Effect of Abutment Connection Type and Cyclic Loading on Removal Torque Value

Background and Aim: Maintaining the primary torque of the abutment screw is a common problem related to implant-supported restorations; a failure in this respect often leads to screw loosening. The abutment screw plays a critical role in the long-term stability of restorations. This study aimed to assess the effect of two abutment connection types with and without cyclic loading on removal torq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical oral implants research

دوره 26 4  شماره 

صفحات  -

تاریخ انتشار 2015