Evaluation of Associated Uncertainties in Calibration of Direct Pressure Indicating Electromechanical Devices

نویسندگان

  • S. Yadav
  • V. K. Gupta
  • O. Prakash
  • A. K. Bandyopadhyay
چکیده

A wide range of direct pressure measuring electromechanical transducers is now commercially available in the market. In such electromechanical type direct indicating devices, the applied pressure is directly measured by a sensing element with a suitable mechanism into an analog / digital electrical signal in terms of voltage, current or frequency. The generation of such signals is based upon some electromechanical effects viz. inductive, capacitive, resistive, piezoelectric, piezoresistive, reluctive, resonative and optoelectric etc. A wide range of such pressure measuring instruments is now commercially available in the market. The high-pressure technology and new applications demand that the best instrumentation should ensure the lowest measurement uncertainty, particularly in the fluid media. The calculation of the calibration results and associated uncertainties is a complex matter involving many influencing quantities. The present paper describes a novel method for evaluating uncertainty in pressure measurement using electromechanical type direct pressure indicating devices through statistical analysis of errors. The method of evaluation of associated uncertainties is in line with ISO and EA Guidelines on the evaluation and expression of uncertainty in measurement. The results thus obtained are compared with the results obtained by using standard technique described in EA guidelines. Both the methods are quite comparable.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

Robust Fractional Order Control of Under-actuated Electromechanical System

This paper presents a robust fractional order controller for flexible-joint electrically driven robots under imperfect transformation of control space. The proposed approach is free from manipulator dynamics, thus free from problems associated with torque control strategy in the design and implementation. As a result, the proposed controller is simple, fast response and superior to the torque c...

متن کامل

Robust Fractional Order Control of Under-actuated Electromechanical System

This paper presents a robust fractional order controller for flexible-joint electrically driven robots under imperfect transformation of control space. The proposed approach is free from manipulator dynamics, thus free from problems associated with torque control strategy in the design and implementation. As a result, the proposed controller is simple, fast response and superior to the torque c...

متن کامل

Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries

Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...

متن کامل

Impact of Measuring Devices and Data Analysis on the Determination of Gas Membrane Properties

The time-lag method, using a gas permeation experiment, is currently the most popular method for determining the membrane properties: diffusivity coefcient and permeability coefcient, and from which the solubility coefcient can be calculated. In this investigation, the impact of systematic, random (noise), resolution and extrapolation errors associated with gas permeatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005