Partial volume correction of brain perfusion estimates using the inherent signal data of time-resolved arterial spin labeling.
نویسندگان
چکیده
Quantitative perfusion MRI based on arterial spin labeling (ASL) is hampered by partial volume effects (PVEs), arising due to voxel signal cross-contamination between different compartments. To address this issue, several partial volume correction (PVC) methods have been presented. Most previous methods rely on segmentation of a high-resolution T1 -weighted morphological image volume that is coregistered to the low-resolution ASL data, making the result sensitive to errors in the segmentation and coregistration. In this work, we present a methodology for partial volume estimation and correction, using only low-resolution ASL data acquired with the QUASAR sequence. The methodology consists of a T1 -based segmentation method, with no spatial priors, and a modified PVC method based on linear regression. The presented approach thus avoids prior assumptions about the spatial distribution of brain compartments, while also avoiding coregistration between different image volumes. Simulations based on a digital phantom as well as in vivo measurements in 10 volunteers were used to assess the performance of the proposed segmentation approach. The simulation results indicated that QUASAR data can be used for robust partial volume estimation, and this was confirmed by the in vivo experiments. The proposed PVC method yielded probable perfusion maps, comparable to a reference method based on segmentation of a high-resolution morphological scan. Corrected gray matter (GM) perfusion was 47% higher than uncorrected values, suggesting a significant amount of PVEs in the data. Whereas the reference method failed to completely eliminate the dependence of perfusion estimates on the volume fraction, the novel approach produced GM perfusion values independent of GM volume fraction. The intra-subject coefficient of variation of corrected perfusion values was lowest for the proposed PVC method. As shown in this work, low-resolution partial volume estimation in connection with ASL perfusion estimation is feasible, and provides a promising tool for decoupling perfusion and tissue volume.
منابع مشابه
A Two-Stage Model for In Vivo Assessment of Brain Tumor Perfusion and Abnormal Vascular Structure Using Arterial Spin Labeling
The ability to assess brain tumor perfusion and abnormalities in the vascular structure in vivo could provide significant benefits in terms of lesion diagnosis and assessment of treatment response. Arterial spin labeling (ASL) has emerged as an increasingly viable methodology for non-invasive assessment of perfusion. Although kinetic models have been developed to describe perfusion in healthy t...
متن کاملSupport vector machine classification of arterial volume‐weighted arterial spin tagging images
INTRODUCTION In recent years, machine-learning techniques have gained growing popularity in medical image analysis. Temporal brain-state classification is one of the major applications of machine-learning techniques in functional magnetic resonance imaging (fMRI) brain data. This article explores the use of support vector machine (SVM) classification technique with motor-visual activation parad...
متن کاملLimitations of a multiplicative correction of partial volume effects on the arterial input function in bolus-tracking perfusion
Introduction: Quantification of cerebral blood flow (CBF) using bolus-tracking MRI is critically dependent on correct determination of the arterial input function (AIF) (1,2). The AIF is the concentration of tracer which enters the brain as a function of time. It is sampled in a supplying artery, which is often subject to a partial volume effect (PVE) due to the limited spatial resolution resul...
متن کاملValidation of diffuse correlation spectroscopy measurements of rodent cerebral blood flow with simultaneous arterial spin labeling MRI; towards MRI-optical continuous cerebral metabolic monitoring
Cerebral blood flow (CBF) during stepped hypercapnia was measured simultaneously in the rat brain using near-infrared diffuse correlation spectroscopy (DCS) and arterial spin labeling MRI (ASL). DCS and ASL CBF values agree very well, with high correlation (R=0.86, p< 10(-9)), even when physiological instability perturbed the vascular response. A partial volume effect was evident in the smaller...
متن کاملPartial Volume Correction for Perfusion Estimation from Multi-TI Arterial Spin Labelling
Introduction: Partial volume (PV) effects, arising from grey matter (GM), white matter (WM) and cerebrospinal fluid (CSF), are known to introduce errors in quantitative perfusion imaging. Furthermore, in patients where tissue atrophy is significant, quantitative perfusion errors due to PV effects may prevent accurate blood flow from being determined. While ASL spatial resolution is improving, r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NMR in biomedicine
دوره 27 9 شماره
صفحات -
تاریخ انتشار 2014