Gynecare Morcellex Sigma(®): Manufacturer: ETHICON Women's Health & Urology, A Division of ETHICON, INC., a Johnson & Johnson company, Somerville, NJ 08876-0151, USA, © ETHICON, INC. 2005.

نویسنده

  • Avishalom Sharon
چکیده

The use of electronic power morcellators in gynecological laparoscopy has been long established. New trends in treatment approaches for intramural and subserosal uterine myomas, and most importantly the introduction of laparoscopic supracervical hysterectomy, required development of new advanced systems, which further simplified the application of safe and efficient morcellators [1, 2]. In the last few years, laparoscopic surgeries together with the more recent addition of robotic surgeries have allowed us to perform advanced operations in the gynecological field, including resection of large uteri up to 22 weeks (measured as size of a pregnant uterus) either total hysterectomy or supracervical hysterectomy and dissection of large and many uterine myomas. In such cases, the use of a well-designed morcellator is paramount for the ease of the patient (i.e., less operation/anesthesia time, no need for laparotomy, etc.) and for the surgeon (i.e., lightweight479 gr, ergonomically adapted) [2–4]. The Gynecare Morcellex Sigma is a brand new tissue morcellator designed for the above-mentioned purposes [2, 4]. The fibroid uterus can have multiple myomas which vary in size, shape, and consistency. The surgeon has to overcome these challenges. The Gynecare Morcellex Sigma is a third-generation morcellator (Diva-1999, Morcellex-2006) Sharon A. (&), Head of The Gyneco-Endoscopic Unit Department of Obstetrics and Gynecology, Hillel-Yaffe Medical Center, Hadera, Israel e-mail: [email protected]

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of different suture materials on tissue healing

PURPOSE The purpose of this study was to investigate the healing differences in between four different widely used suture materials in the oral surgery practice, including silk (Perma- Hand; Ethicon, INC., Somerville, NJ, USA), polypropylene (Prolene; Ethicon, INC., Somerville, NJ, USA), coated polyglactin 910 (Ethicon, INC., Somerville, NJ, USA). and polyglecaprone 25 (Ethicon, INC., Somervill...

متن کامل

Structural differences and architectural features of two different polypropylene slings (TVT-O and I-STOP) have no impact on biocompatibility and tissue reactions

INTRODUCTION To evaluate the impact of design features of the synthetic mid-urethral slings on tissue integrity and inflammatory responses. MATERIAL AND METHODS In total 30 female Sprague-Dawley rats were implanted with type I monofilamentous, macroporous polypropylene meshes: Gynecare TVT-Obturator tape® (Ethicon Inc., Johnson & Johnson, Somerville, NJ, USA) and I-STOP® (CL Medical Inc., Lyo...

متن کامل

SUMMARY OF CONSENSUS OPINION Scientific Panel on GYNECARE VERSAPOINT

On September 22, 2000, GYNECARE, a division of ETHICON, INC., undertook a voluntary global withdrawal of the GYNECARE VERSAPOINT Bipolar Electrosurgery System electrodes and handpieces in response to a small number of spontaneous reports of non-fatal air and gas embolism associated with use of the system during hysteroscopic myomectomy procedures. This withdrawal was performed in the interest o...

متن کامل

Surgical intervention for stress urinary incontinence: comparison of midurethral sling procedures.

CONTEXT The synthetic, tension-free midurethral sling was introduced in the 1990s as a surgical treatment for women with stress urinary incontinence (SUI). Several similar products are now available. The authors generated data comparing clinical outcomes of two midurethral sling procedures. OBJECTIVE To compare clinical outcomes of two midurethral sling procedures currently used for the treat...

متن کامل

Comparison of absorbable with nonabsorbable sutures in closure of facial skin wounds.

BACKGROUND There is long-standing disagreement among facial plastic surgeons as to the ideal suture material for closing skin wounds of the face. Many surgeons believe that nonabsorbable suture material is preferable, as it is easier to tie, is unlikely to break prematurely, and elicits a minimal inflammatory response. Others feel that these issues are of minor importance and prefer absorbable ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of obstetrics and gynaecology of India

دوره 64 3  شماره 

صفحات  -

تاریخ انتشار 2014