Mono-Exponential Fitting in T2-Relaxometry: Relevance of Offset and First Echo
نویسندگان
چکیده
INTRODUCTION T2 relaxometry has become an important tool in quantitative MRI. Little focus has been put on the effect of the refocusing flip angle upon the offset parameter, which was introduced to account for a signal floor due to noise or to long T2 components. The aim of this study was to show that B1 imperfections contribute significantly to the offset. We further introduce a simple method to reduce the systematic error in T2 by discarding the first echo and using the offset fitting approach. MATERIALS AND METHODS Signal curves of T2 relaxometry were simulated based on extended phase graph theory and evaluated for 4 different methods (inclusion and exclusion of the first echo, while fitting with and without the offset). We further performed T2 relaxometry in a phantom at 9.4T magnetic resonance imaging scanner and used the same methods for post-processing as in the extended phase graph simulated data. Single spin echo sequences were used to determine the correct T2 time. RESULTS The simulation data showed that the systematic error in T2 and the offset depends on the refocusing pulse, the echo spacing and the echo train length. The systematic error could be reduced by discarding the first echo. Further reduction of the systematic T2 error was reached by using the offset as fitting parameter. The phantom experiments confirmed these findings. CONCLUSION The fitted offset parameter in T2 relaxometry is influenced by imperfect refocusing pulses. Using the offset as a fitting parameter and discarding the first echo is a fast and easy method to minimize the error in T2, particularly for low to intermediate echo train length.
منابع مشابه
An automatic method for myocardial T2* curve fitting in thalassemia patients with severe iron overload
Background Myocardial iron overload assessment by multislice multiecho T2* technique is used in the clinical management of thalassemia major (TM) patients. Signal decay curves are extracted from the 16 left ventricular (LV) segments and the fitting of these curves to a mono-exponential model provides the corresponding T2* values. In patients with severe cardiac iron overload, where signal will ...
متن کاملNovel MRI T2 Mapping for Improved Myocardial Tissue Characterisation
Introduction: As part of our work on myocardial iron quantification we have developed an breath-hold fast spin echo (FSE) T2 technique with good reproducibility (1,2). This T2 technique, however, is based on region-ofinterest (ROI) analysis. Although ROI analysis can increase signal to noise ratio (SNR), it may introduce errors to T2 measurement by averaging every pixel within the region. By co...
متن کاملInter-site validations of the Pixel-Wise method for cardiac T2* analysis in transfusion-dependent Thai thalassemia patients.
OBJECTIVE To compare inter-site observer variability of the Pixel- Wise (PW) method for cardiac T2* analysis in thalassemia patients using the mono-exponential with a constant fitting (offset) model and to compare the cross-model variability of the offset model to the mono-exponential (typical) model. MATERIAL AND METHOD Eighty-eight cardiac T2* measurements were performed on 72 Thalassemia m...
متن کاملMeasurement of T1 of the Ultrashort T2* Components in White Matter of the Brain at 3T
Recent research demonstrates that white matter of the brain contains not only long T2 components, but a minority of ultrashort T2* components. Adiabatic inversion recovery prepared dual echo ultrashort echo time (IR-dUTE) sequences can be used to selectively image the ultrashort T2* components in white matter of the brain using a clinical whole body scanner. The T2*s of the ultrashort T2* compo...
متن کاملMulti-Compartment T2 Relaxometry Using a Spatially Constrained Multi-Gaussian Model
The brain's myelin content can be mapped by T2-relaxometry, which resolves multiple differentially relaxing T2 pools from multi-echo MRI. Unfortunately, the conventional fitting procedure is a hard and numerically ill-posed problem. Consequently, the T2 distributions and myelin maps become very sensitive to noise and are frequently difficult to interpret diagnostically. Although regularization ...