Percutaneous Vacuum-Assisted Thrombectomy Device Used for Removal of Large Vegetations on Infected Pacemaker and Defibrillator Leads as an Adjunct to Lead Extraction.
نویسندگان
چکیده
This case series reports our early experience with a minimally invasive percutaneous method of safely removing large vegetations during lead extraction in septic cardiac implantable electronic devices (CIED). Debate exists concerning the management of vegetations involving these devices. Lead extraction is mandated for infections, but vegetations may embolize, causing complications. Surgical debridement is recommended; alternatives include cardiopulmonary bypass, minimally invasive thoracotomy, or transatrial approaches. The AngioVac device allows percutaneous right heart bypass and suction removal of vegetations under echocardiographic and fluoroscopic guidance. This case series describes our first 20 patients, all critically ill with persistent sepsis and vegetations despite long-term antibiotics. This series includes patients who would not have been eligible for alternative procedures due to contraindications and highlights the potential role of this new technology.
منابع مشابه
Simultaneous lead extraction and vacuum-assisted vegetation removal
The incidence of infection associated with cardiac implantable electronic devices (CIEDs) is rising at a rate faster than that of the number of implants. CIED infections typically require complete device and lead removal. The prevalence of vegetations is high in patients with infective indications who are referred for lead extraction. Because of the risk of hemodynamically significant pulmonary...
متن کاملTransvenous Pacemaker Lead Removal in Pacemaker Lead Endocarditis with Large Vegetations: A Report of Two Cases
Pacemaker lead endocarditis is treated with total removal of the infected device and proper antibiotics. The outcomes of patients undergoing percutaneous lead extraction for large vegetations (>2 cm) have not yet been shown. In this case report, we present two patients with pacemaker lead endocarditis with large vegetations of maximum diameter 2.4 cm and 3.2 cm. The first patient had multiple v...
متن کاملPercutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads
BACKGROUND Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. METHODS Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead re...
متن کاملSuccessful percutaneous extraction of pacemaker leads with a novel (VascoExtor) pacing lead removal system.
A new pacing lead extraction system (VascoExtor, VascoMed, Germany) with a universally applicable locking stylet was used over a period of 12 months to extract 25 permanent pacemaker leads (mean implantation time 3.9 +/- 3.8 years) in 16 patients who had pacemaker infection (n = 13), lead dysfunction (n = 2), or before an automatic defibrillator implant (n = 1). With use of this system, we were...
متن کاملPacemaker endocarditis: approach for lead extraction in endocarditis with large vegetations.
We present the case of a patient with vegetations on a pacing lead from a pacemaker implanted 13 years previously. A new surgical technique for removal of infected leads was developed to avoid the increased risk of septic pulmonary embolism. The electrode with vegetations was removed without cardiopulmonary bypass using the direct surgical approach described.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of atrial fibrillation
دوره 9 3 شماره
صفحات -
تاریخ انتشار 2016