Blood clotting in minimally altered whole blood.
نویسندگان
چکیده
The sequences of events regulating thrombin generation during tissue factor-initiated clotting in whole blood at 37 degrees C in which the contact pathway was suppressed with corn trypsin inhibitor are studied using quantitative Western blotting of factor V, prothrombin, platelet factor 4, antithrombin III, and fibrinogen. In addition, fibrinopeptide A (FPA), thrombin-antithrombin III (TAT) complex formation, and prothrombin fragment 1.2 (F1.2) were measured via commercially available enzyme-linked immunosorbent assays (ELISAs). In a typical experiment initiated with 40 pmol/L recombinant tissue factor, visual clot time (4.5 minutes), was preceded by significant cleavage of factor V resulting in 65% factor Va heavy-chain generation but only 10% light-chain formation. At this point, 50% of the platelet factor 4 is released, suggesting that half (approximately 700 pmol/L) of the platelet prothrombinase sites available have been generated. At clot time, approximately 15 nmol/L thrombin B-chain is present; however, analyses of FPA release demonstrate that only 15% of the thrombin is acting on fibrinogen. This thrombin is produced by the action of 7 pmol/L prothrombinase. The maximum rate of thrombin production is reached well after clot time and is consistent with the presence of approximately 150 pmol/L prothrombinase (at about 7 minutes). These results suggest that factor Xa is the limiting factor for thrombin generation. After 60 minutes, 75% of the initial prothrombin (1.24 mumol/L) is consumed yielding 400 nmol/ L prethrombin 2 and 360 nmol/l thrombin (B-chain) products. The sum of these values (800 nmol/L) is similar to the (corrected) F1.2 concentration determined by ELISA. The incomplete cleavage of prothrombin indicates both the prothrombinase complex and the formation of prothrombinase are inhibited in the reaction. TAT complex measured by ELISA is almost equivalent to B-chain concentration, but sodium dodecyl sulfate stable thrombin-antithrombin III complexes are not observed until well after clot formation and are never equivalent to ELISA-TAT values. At the point of clot formation, 80% of the fibrinogen is depleted from the fluid phase, whereas only 35% to 45% of the FPA is released, suggesting a significant incorporation of uncleaved fibrinogen into the initial clot formed.
منابع مشابه
Blood Clotting in Minimally Altered Whole Blood
The sequences of events regulating thrombin generation during tissue factor-initiated clotting in whole blood at 37°C in which the contact pathway was suppressed with corn trypsin inhibitor are studied using quantitative Western blotting of factor V, prothrombin, platelet factor 4, antithrombin Ill, and fibrinogen. In addition, fibrinopeptide A (FPA), thrombin-antithrombin 111 (TAT) complex for...
متن کاملEffect of whole blood clotting time in rats with ionized hypocalcemia induced by rapid intravenous citrate infusion.
Although the toxic effects of citrate including hemodynamic and cardiovascular changes result from a decrease in ionized calcium levels in serum due to chelating action, these effects of citrate on blood coagulation have not yet been fully clarified. The present study examines whether serum citrate and ionized calcium levels affect whole blood clotting time in rats using the test tube method in...
متن کاملThe role of platelets in blood coagulation--effects of platelet agonists and GPIIb/IIIa inhibitors studied by free oscillation rheometry.
We have studied the contribution of platelets to the coagulation of plasma and the effects of activation or inhibition of platelets on the coagulation process in unanticoagulated fresh whole blood (subsequently termed native blood). For this purpose, we have used a free oscillation rheometer (FOR), the ReoRox4, a new instrument that enables noninvasive viscoelastic measurements of clot formatio...
متن کاملExperimental hypercalcaemia and whole blood clotting.
Experimental hypercalcaemia was induced in rats by (1) transplantation of the solid Walker 256 tumour, and (2) intraperitoneal injections of calcium gluconate. Whole blood clotting was studied by means of thromboelastography and whole blood clotting times in polystyrene and glass test tubes. At serum calcium levels between 10.3 and 11.5 m-equiv/l a slight delay in clot formation was found which...
متن کاملEvaluation of the SonoClot Analyzer for the measurement of platelet function in whole blood.
A viscoelastometer, the SonoClot Coagulation Analyzer, has been proposed for use in the evaluation of platelet function. The purpose of this study was to evaluate systematically this instrument when used with whole blood. Under laboratory conditions, the coefficient of variation (cv) of determinations of whole blood activated clotting time (ACT) on the instrument was approximately 7.0 percent. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Blood
دوره 88 9 شماره
صفحات -
تاریخ انتشار 1996