Bronchodilator therapy with metered-dose inhaler and spacer versus nebulizer in mechanically ventilated patients: comparison of magnitude and duration of response.
نویسندگان
چکیده
OBJECTIVE Four-hour comparison of the bronchodilator response of albuterol administered via metered-dose inhaler (MDI) with spacer versus small-volume nebulizer (SVN) to mechanically ventilated patients with chronic obstructive pulmonary disease (COPD). DESIGN Prospective randomized clinical trial. SETTING Medical intensive care unit in a university hospital. PATIENTS Thirteen mechanically ventilated COPD patients. INTERVENTION Albuterol administration of 4 puffs (0.4 mg) or 10 puffs (1.0 mg) via MDI with spacer or 2.5 mg via SVN to mechanically ventilated patients in order to assess the bronchodilator response over 4 hours. MEASUREMENTS AND RESULTS Mechanically ventilated patients were enrolled in a randomized crossover study wherein one group received 4 puffs (0.4 mg) or 2.5 mg of albuterol and another group received 10 puffs (1.0 mg) or 2.5 mg of albuterol on separate days. Respiratory mechanics measurements were obtained over 4 hours. Total airway resistance declined by 14.4 +/- 3.8% after 4 MDI puffs, 18.3 +/- 1.8% after 10 MDI puffs, or 13.7 +/- 2.6% after 2.5 mg via SVN, compared to baseline (p < 0.01). After albuterol delivery, airway resistance remained improved for 90-120 minutes (p < 0.05) and returned to baseline by 4 hours with all treatments. CONCLUSION The airway response to albuterol administration via MDI and SVN to mechanically ventilated patients was similar in magnitude and duration, returning to baseline by 240 minutes. In stable, mechanically ventilated COPD patients, albuterol may be administered via MDI with spacer or via SVN every 4 hours.
منابع مشابه
Bronchodilator delivery with metered-dose inhaler during mechanical ventilation
The delivery of bronchodilators with metered-dose inhaler (MDI) in mechanically ventilated patients has attracted considerable interest in recent years. This is because the use of the MDI has several advantages over the nebulizer, such as reduced cost, ease of administration, less personnel time, reliability of dosing and a lower risk of contamination. A spacer device is fundamental in order to...
متن کاملBronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of end-inspiratory pause.
The delivery of bronchodilators with a metered-dose inhaler (MDI) and a spacer in mechanically ventilated patients has become widespread practice. However, the various ventilator settings that influence the efficacy of MDI are not well established. Application of an end-inspiratory pause (EIP) during drug delivery has been suggested as one of the factors that might increase the effectiveness of...
متن کاملDomiciliary comparison of terbutaline treatment by metered dose inhaler with and without conical spacer in severe and moderately severe chronic asthma.
The bronchodilator response to cumulative doses of terbutaline administered by metered dose inhaler with and without a conical spacer device and by Acorn nebuliser has been compared in groups of patients with chronic severe and moderately severe asthma. After laboratory studies the patients undertook a randomised domiciliary crossover comparison of bronchodilator response to terbutaline given b...
متن کاملInhalation therapy with metered-dose inhalers and dry powder inhalers in mechanically ventilated patients.
Pressurized metered-dose inhalers (pMDIs) are commonly employed for administering bronchodilator aerosols to mechanically ventilated patients. Although it is feasible to employ dry powder inhalers in ventilator circuits, the presence of humidity in the ventilator circuit could reduce their efficiency. A complex array of factors influence drug delivery from pMDIs during mechanical ventilation, a...
متن کاملBronchodilator delivery by metered-dose inhaler in mechanically ventilated COPD patients: influence of flow pattern.
In mechanically ventilated patients the flow pattern during bronchodilator delivery by metered-dose inhaler (MDI) could be a factor that might influence the effectiveness of this therapy. In order to test this the effect of two different inspiratory flow patterns on the bronchodilation induced by beta2-agonists administered via MDI and spacer in a group of mechanically ventilated patients with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Respiratory care
دوره 45 7 شماره
صفحات -
تاریخ انتشار 2000