Improving the reliability of multiplexed fiber optic low-coherence interferometric sensors by use of novel twin-loop network topologies.
نویسندگان
چکیده
Novel twin-loop network topologies for multiplexing fiber optic low-coherence reflectometric sensors are proposed and theoretically analyzed. The sensing fibers are made by connecting segments of standard single-mode fibers with partial reflections at the fiber joints and are completely passive. Absolute length measurement can be made for each segment of the sensing fiber so that strain or temperature distribution along the entire sensing fiber can be derived. It is expected that novel topologies would help as to improve the reliability of the sensor network by providing multiple accesses to each of the sensing segment so that most of the sensing segments can still be interrogated even when one or more point breakages occur along the transmission fibers. A nine-sensor twin-loop sensing network was constructed and experimentally tested by use of a Michelson low-coherence interferometer, and the results obtained agree with our theoretical prediction. The novel network topologies may be used for large-scale smart structure applications where breakages of transmission fibers may occur during the stages of sensor imbedding, installation, and structure-in-service cycles.
منابع مشابه
Low-coherence Michelson interferometric fiber-optic multiplexed strain sensor array: a minimum configuration.
A minimum configuration Michelson fiber-optic low-coherence interferometric quasi-distributed sensing system is proposed that permits absolute length measurement in remote reflective sensor arrays. The sensor's reflective signal characteristics have been analyzed, and the relationship between intensities of light and number of sensors is given for evaluation of multiplexing potential. The propo...
متن کاملProgressive ladder network topology combining interferometric and intensity fiber-optic-based sensors.
Progressive ladder topology is studied by consideration of its properties of power budget and coupler tailoring. Optimization criteria are addressed for lossless and real systems, and their basic characteristics are compared with other topologies. Numerical results are presented, and an experiment is described for the case in which the network supports interferometric and intensity (with refere...
متن کاملIntrinsic Fabry-Perot Interferometric Fiber Sensor Based on Ultra-Short Bragg Gratings for Quasi-Distributed Strain and Temperature Measurements
(Abstract) The health monitoring of smart structures in civil engineering is becoming more and more important as in-situ structural monitoring would greatly reduce structure life-cycle costs and improve reliability. The distributed strain and temperature sensing is highly desired in large structures where strain and temperature at over thousand points need to be measured simultaneously. It is d...
متن کاملHealth monitoring of a full composite CNG tanks using long-gage fiber optic sensors
The Compressed Natural Gas (CNG) used as a carburant in automotive industry offers low cost and notably less pollution. Full composite tank used to store the CNG onboard features low weight and extended lifespan. However, the safety issues and maintenance fees remain a challenge for its use in ordinary cars. The structural health monitoring of tanks with accent to damage detection can significa...
متن کاملNovel Fiber-Optic Ring Acoustic Emission Sensor
Acoustic emission technology has been applied to many fields for many years. However, the conventional piezoelectric acoustic emission sensors cannot be used in extreme environments, such as those with heavy electromagnetic interference, high pressure, or strong corrosion. In this paper, a novel fiber-optic ring acoustic emission sensor is proposed. The sensor exhibits high sensitivity, anti-el...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Review of scientific instruments
دوره 78 5 شماره
صفحات -
تاریخ انتشار 2007