Physician and patient exposure during cardiac catheterization.

نویسنده

  • F G Rueter
چکیده

A survey of the literature was conducted to establish the anticipated ranges of exposure to both physicians and patients during cardiac catheterization. A brief explanation of a technic for using time-lapse photography and a computer model for exposure calculation is presented. The thermoluminescent dosimeter (TLD) results used as controls for exposure values calculated by the developed technique are presented in detail. Physician eye exposures of approximately 20 mR per cardiac catheterization procedure were measured, which would suggest a limit of five procedures per week for physicians. The average patient skin entrance exposure of 28 R is high, as is the 12 mR gonadal exposure; however, they are accepted because of the possible benefits of the procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

عوامل تاثیر گذار بر شدت کمردرد بیماران بعد از آنژیوگرافی قلبی

  Background and Aim: Cardiac catheterization is a widely used cardiac investigation procedure in Iran. However, back pain is frequently reported following cardiac catheterization due to prolonged bed rest after the procedure. There is no research about factors that affect back pain. This study was designed to explore these factors in patients admitted to Taleghani hospital for cardiac catheter...

متن کامل

Effect of a real-time radiation monitoring device on operator radiation exposure during cardiac catheterization: the radiation reduction during cardiac catheterization using real-time monitoring study.

BACKGROUND The Radiation Reduction During Cardiac Catheterization Using Real-Time Monitoring study sought to examine the effect of a radiation detection device that provides real-time operator dose reporting through auditory feedback (Bleeper Sv; Vertec Scientific Ltd; Berkshire, UK) on patient dose and operator exposure during cardiac catheterization. METHODS AND RESULTS Between January 2012...

متن کامل

Radiation Dose Reduction during Radial Cardiac Catheterization: Evaluation of a Dedicated Radial Angiography Absorption Shielding Drape

Objectives. Radiation scatter protection shield drapes have been designed with the goal of decreasing radiation dose to the operators during transfemoral catheterization. We sought to investigate the impact on operator radiation exposure of various shielding drapes specifically designed for the radial approach. Background. Radial access for cardiac catheterization has increased due to improved ...

متن کامل

Hemodynamic studies in pectus excavatum.

Method of Study The patients reported in this series were seen as routine referrals to the cardiac clinic of the City of Hope Medical Center during the course of one calendar year. In each instance, the patient was thought by his referring physician to have organic heart disease. In addition to routine 14-lead electrocardiograms, each patient had a vectorcardiogram made with 3-lead systems (Kim...

متن کامل

A catheter malpositioned patient with pain and paresthesia

We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 58 1  شماره 

صفحات  -

تاریخ انتشار 1978