Application of different Scheimpflug-based lens densitometry methods in phacodynamics prediction.

نویسندگان

  • Fernando Faria-Correia
  • Bernardo T Lopes
  • Isaac C Ramos
  • Tiago Monteiro
  • Nuno Franqueira
  • Renato Ambrósio
چکیده

PURPOSE To evaluate the correlations between preoperative Scheimpflug-based lens densitometry metrics and phacodynamics. METHODS The Lens Opacities Classification System III (LOCS III) was used to grade nuclear opalescence (NO), along with different methods of lens densitometry evaluation (absolute scale from 0% to 100%): three-dimensional (3D), linear, and region of interest (ROI) modes. Cumulative dissipated energy (CDE) and total ultrasound (US) time were recorded and correlated with the different methods of cataract grading. Significant correlations were evaluated using Pearson or Spearman correlation coefficients according to data normality. RESULTS A positive correlation was detected between the NO score and the average density and the maximum density derived from the 3D mode (r=0.624, P<0.001; r=0.619, P<0.001, respectively) and the ROI mode (r=0.600, P<0.001; r=0.642, P<0.001, respectively). Regarding the linear mode, only the average density parameter presented a significant relationship with the NO score (r=0.569, P<0.001). The 3D-derived average density and maximum density were positively correlated with CDE (rho =0.682, P<0.001; rho =0.683, P<0.001, respectively) and total US time (rho =0.631 and rho =0.668, respectively). There was a linear relationship between the average density and maximum density of the ROI mode and CDE (rho =0.686, P<0.001; rho =0.598, P<0.001, respectively) and total US time (rho =0.642 and rho =0.644, respectively). The average density was the only parameter derived from the linear mode that showed a significant correlation with CDE (rho =0.522, P<0.001) and total US time (rho =0.450, P<0.001). CONCLUSION Specific Scheimpflug-derived densitometric parameters of the nucleus correlated with phacoemulsification parameters. The use of the appropriate densitometry approach can predict more efficiently the phacodynamics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation of age-related cataract density graded by the Scheimpflug Imaging System with visual function and phacoemulsification energy.

The purpose of this study is to investigate the relationship between lens density in age-related cataract and best-corrected visual acuity (BCVA) and the impact of cataract grade assessed via 3D lens densitometry by Pentacam Nucleus Grading System (PNS) on Phacodynamics (phaco-time and phaco-energy). To achieve the aim 55 patients with age-related cataract were evaluated. Lens density was asses...

متن کامل

Repeatability and validity of lens densitometry measured with Scheimpflug imaging.

PURPOSE To assess the repeatability and validity of lens densitometry derived from the Pentacam Scheimpflug imaging system. SETTING Eye Clinic, Queensland University of Technology, Brisbane, Australia. METHODS This prospective cross-sectional study evaluated 1 eye of subjects with or without cataract. Scheimpflug measurements and slitlamp and retroillumination photographs were taken through...

متن کامل

Scheimpflug lens densitometry and ocular wavefront aberrations in patients with mild nuclear cataract.

PURPOSE To test correlations between Scheimpflug optical densitometry and ocular higher-order aberrations (HOAs) in patients with mild nuclear cataract. SETTING Cornea and Refractive Surgery Department, Hospital de Braga, Braga, Portugal. DESIGN Retrospective single-center study. METHODS In eyes with mild nuclear cataract, lens densitometry was evaluated by Scheimpflug imaging (Pentacam H...

متن کامل

Study of nuclear cataract progression using the National Eye Institute Scheimpflug system.

AIMS A study was conducted to determine the capability of the recently developed National Eye Institute (NEI) Scheimpflug cataract imaging system in detecting changes in the nuclear region of the lens over a 1 year period. METHODS Twenty five eyes with pure nuclear cataracts with mean nuclear densities < or = 0.30 optical density units (ODU) as well as 30 normal control eyes were each examine...

متن کامل

Lens Densitometry after Corneal Cross-linking in Patients with Keratoconus Using a Scheimpflug Camera

PURPOSE To evaluate changes in crystalline lens densitometry following corneal cross-linking (CXL) in keratoconic patients. METHODS In a quasi-experimental study, three-dimensional lens densitometry was performed using the Pentacam Scheimpflug camera (Oculus Optikgerate GmbH, Wetzlar, Germany) at baseline and six months after CXL. Densitometry was performed in a fixed area of 2 inch × 1 inch ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical ophthalmology

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016