Cement leakage causes potential thermal injury in vertebroplasty

نویسندگان

  • Po-Liang Lai
  • Ching-Lung Tai
  • Lih-Huei Chen
  • Nai-Yuan Nien
چکیده

BACKGROUND Percutaneous vertebroplasty by injecting PMMA bone cement into the fractured vertebrae has been widely accepted in treatment of spinal compression fracture. However, the exothermic polymerization of bone cement may cause osseous or neural tissue injury. This study is thus designed to evaluate the potential risk of thermal damage in percutaneous vertebroplasty. METHOD Twelve porcine vertebrae were immersed in 37°C saline for the experiment. In the first stage of the study, vertebroplasty without cement leakage (control group, n = 6) was simulated. The anterior cortex, foramen, posterior cortex and the center of the vertebral body were selected for temperature measurement. Parameters including peak temperature and duration above 45°C were recorded. In the second stage, a model (n = 6) simulating bone cement leaking into the spinal canal was designed. The methods for temperature measurement were identical to those used in the first stage. RESULTS In Stage 1 of the study (vertebroplasty of the porcine vertebral body in the absence of cement leakage), the average maximal temperature at the anterior cortex was 42.4 ± 2.2°C; at the neural foramen 39.5 ± 2.1°C; at the posterior cortex 40.0 ± 2.5°C and at the vertebral center, 68.1 ± 3.4°C. The average time interval above 45°C was 0 seconds at the anterior cortex; at the neural foramen, 0 seconds; at the posterior cortex, 0 seconds and at the vertebral center, 223 seconds. Thus, except at the core of the bone cement, temperatures around the vertebral body did not exceed 45°C. In Stage 2 of the study (cement leakage model), the average maximal temperature at the anterior cortex was 42.7 ± 2.4°C; at the neural foramen, 41.1 ± 0.4°C; at the posterior cortex, 59.1 ± 7.6°C and at the vertebral center, 77.3 ± 5.7°C. The average time interval above 45°C at the anterior cortex was 0 seconds; at the neural foramen, 0 seconds; at the posterior cortex, 329.3 seconds and at the vertebral center, 393.2 seconds. Based on these results, temperatures exceeded 45°C at the posterior cortex and at the vertebral center. CONCLUSIONS The results indicated that, for bone cement confined within the vertebra, curing temperatures do not directly cause thermal injury to the nearby soft tissue. If bone cement leaks into the spinal canal, the exothermic reaction at the posterior cortex might result in thermal injury to the neural tissue.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraspinal leakage of bone cement after vertebroplasty: a report of 3 cases.

We report 3 cases of vertebroplasty-induced intraspinal leakage of bone cement that were referred to us for management. Two patients received decompressive surgery, and one received rehabilitation. The gross surgical finding of yellowish dura mater and intradural fibrosis, adhesion, and microscopic finding of arachnoid membrane fibrosis are suggestive of late effect of thermal injury. These pat...

متن کامل

The Potential Impact of Venobasillar System Morphology and Applied Technique on Epidural Cement Leakage with Percutaneous Vertebroplasty.

BACKGROUND Bone cement leakage during vertebroplasty is a frequently reported complication with the potential for neural injury. OBJECTIVE To assess risk factors for epidural cement leakage during vertebroplasty. SETTING Neurosurgical department of a scientific research institute. STUDY DESIGN This is a prospective cross-sectional randomized trial. METHODS Seventy-five patients with int...

متن کامل

Is There a Dose–Response Relationship of Cement Volume With Cement Leakage and Pain Relief After Vertebroplasty?

The aim of this study was to determine if there were dose-response relationships of cement volume with cement leakage and pain relief after percutaneous vertebroplasty (PVP) for osteoporosis vertebral compression fractures (OVCFs). We collected the patient and procedural characteristics on 108 patients with OVCFs in our hospital who received PVP. Univariate and multivariate analyses were perfor...

متن کامل

Epidural cement leakage through pedicle violation after balloon kyphoplasty causing paraparesis in osteoporotic vertebral compression fractures - a report of two cases

Kyphoplasty is advantageous over vertebroplasty in terms of better kyphosis correction and diminished risk of cement extravasations. Literature described cement leakage causing neurological injury mainly after vertebroplasty procedure; only a few case reports show cement leakage with kyphoplasty without neurological injury or proper cause of leakage. We present a report two cases of osteoporoti...

متن کامل

Vertebroplasty: cement leakage into the disc increases the risk of new fracture of adjacent vertebral body.

BACKGROUND AND PURPOSE Patients successfully treated with vertebroplasty often return with new pain caused by a new vertebral body fracture. The new fractures often are adjacent to the vertebral bodies that were initially treated. In our clinical work, we have observed that cement leakage into the disk increases the risk of new fracture of the adjacent vertebral body. This study analyzed the ri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2011