Resynchronization therapy optimization by intracardiac impedance.

نویسندگان

  • Mario Bocchiardo
  • Dorothee Meyer zu Vilsendorf
  • Carmelo Militello
  • Michael Lippert
  • Gerald Czygan
  • Patrick Schauerte
  • Fiorenzo Gaita
  • Christoph Stellbrink
چکیده

AIMS For successful cardiac resynchronization therapy (CRT), an optimization of left ventricular (LV) lead position and stimulation timing is required. The feasibility of optimizing LV lead position, atrioventricular delay (AVd), and interventricular delay (VVd) in CRT using intracardiac impedance measurement was evaluated. METHODS AND RESULTS Heart failure patients (n = 14, NYHA 13×III, 1×II, ejection fraction: 26 ± 6%, QRS: 165 ± 30 ms) were stimulated by AAI and biventricular (DDD-BiV) pacing in turn. Left ventricular lead site, AVd, and VVd were varied. An external pacemaker measured impedance, and a micromanometer catheter measured LV and aortic pressure. Left ventricular dP/dt(max), pulse pressure (PP), stroke volume (SV), end-systolic impedance (ESZ), and stroke impedance (SZ) were determined. Optimization results achieved by maximum increase in PP, SV, SZ, or ESZ were compared with the reference method (dP/dt(max) increase). Left ventricular lead site variation resulted in a mean optimal dP/dt(max) benefit of 18.2%. Lead site selection by SZ/PP/SV showed benefits of 17.4/17.9/17.2%, respectively. Atrioventricular delay optimization increased the optimal benefit to 22.1%, the methods ESZ/PP/SV achieved 20.1/20.8/19.4%. Interventricular delay optimization resulted in a benefit of 19.1/19.4/19.9% (SZ/PP/SV) with an optimum of 21.8%. The achieved benefit did not differ significantly between impedance, SV, and PP methods. A significant correlation between AVd values selected by dP/dt(max) and by the other methods was observed (r = 0.75/0.67/0.60 for ESZ/PP/SV). CONCLUSION The feasibility of optimizing LV lead site, AVd, and VVd by intracardiac impedance has been demonstrated for CRT patients with a similar performance as using SV and PP. Application of intracardiac impedance for automatic implant-based CRT optimization appears to be within reach.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relationship between intracardiac impedance and left ventricular contractility in patients undergoing cardiac resynchronization therapy

AIMS Cardiac resynchronization therapy (CRT) has dramatically improved the symptoms and prognosis of patients with heart failure in large randomized clinical trials. Optimization of device settings may maximize benefit on an individual basis, although the best method for this is not yet established. We evaluated the use of cardiogenic impedance measurements (derived from intracardiac impedance ...

متن کامل

Intracardiac electrogram method of VV-delay optimization in biventricular pacemakers.

Ventricle to ventricle (VV) delay optimization can provide an additional benefit to cardiac resynchronization therapy, but the methods currently used for optimization are time consuming and operator-dependent. We present two cases of VV-delay optimization with the use of a new intracardiac electrogram method. (Cardiol J 2007; 14: 305-310).

متن کامل

Atrioventricular and interventricular delay optimization and response quantification in biventricular pacing: arrival of reliable clinical algorithms and research protocols, and how to distinguish them from unreliable counterparts.

In this issue of the journal, Bogaard et al. assess the achievable haemodynamic increment within individuals of optimizing atrioventricular (AV) and interventricular (VV) delays. Biventricular pacing, or cardiac resynchronization therapy (CRT), arguably the greatest advancement in the treatment of heart failure in the last decade, causes immediate increases in haemodynamics and then improvement...

متن کامل

Comparison of the measured pre-ejection periods and left ventricular ejection times between echocardiography and impedance cardiography for optimizing cardiac resynchronization therapy

BACKGROUND The pre-ejection period (PEP) and left ventricular ejection time (LVET) are easily measured by impedance cardiography (ICG). We hypothesized that the PEP/LVET measured by ICG would correlate with that measured by echocardiography, and that PEP/LVET measured by ICG would be useful for cardiac resynchronization therapy (CRT) optimization. METHODS Newly CRT implanted patients were opt...

متن کامل

Measurement precision in the optimization of cardiac resynchronization therapy.

BACKGROUND Cardiac resynchronization therapy improves morbidity and mortality in appropriately selected patients. Whether atrioventricular (AV) and interventricular (VV) pacing interval optimization confers further clinical improvement remains unclear. A variety of techniques are used to estimate optimum AV/VV intervals; however, the precision of their estimates and the ramifications of an impr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology

دوره 12 11  شماره 

صفحات  -

تاریخ انتشار 2010