A synthetic macromolecule for sentinel node detection: (99m)Tc-DTPA-mannosyl-dextran.

نویسندگان

  • D R Vera
  • A M Wallace
  • C K Hoh
  • R F Mattrey
چکیده

UNLABELLED We report the synthesis and preliminary biologic testing of a synthetic macromolecule, (99m)Tc-diethylenetriaminepentaacetic acid (DTPA)--mannosyl-dextran, for sentinel node detection. METHODS Synthesis started with a 2-step process that attaches a high density of amino-terminated leashes to a dextran backbone. Allyl-bromide was reacted with pharmaceutical-grade dextran to yield allyl-dextran. After diafiltration with water, filtration, and lyophilization, the product was reacted with aminoethanethiol and ammonium persulfate. The resulting amino-conjugated dextran was dialyzed, filtered, and lyophilized. The mixed anhydride method was used to attach DTPA; after dialysis, filtration, and lyophilization, 2-imino-2-methoxyethyl-1-D-mannose was used to attach the receptor substrate. The molecular diameter was measured by dynamic light scattering. Amino, mannose, and DTPA densities were measured by trinitrobenzene sulfonate assay, sulfuric acid/phenol assay, and inductively coupled plasma spectroscopy of gadolinium-DTPA-mannosyl-dextran, respectively. Receptor affinity was measured by Scatchard assay of rabbit liver. Axillary, popliteal, and iliac lymph nodes and each injection site were assayed for radioactivity at 1 and 3 h after injection of approximately 3.7 MBq (0.050 mL) (99m)Tc-DTPA-mannosyl-dextran (0.22 nmol) or filtered (99m)Tc-sulfur colloid into the foot pads. Four animals were studied at each time point. RESULTS DTPA-mannosyl-dextran had a molecular weight of 35,800 g/mol and a molecular diameter of 7.1 nm. The final amine, mannose, and DTPA densities were 23, 55, and 8 mol per dextran. Labeling yields were in excess of 98% and stable for 6 h. Specific activities of 74 x 10(6) GBq/mol were achieved. The equilibrium dissociation constant for binding to the mannose-terminated glycoprotein receptor was 0.12 +/- 0.07 nmol/L. The popliteal extraction at both 1 h and 3 h was significantly (P < 0.05) higher for (99m)Tc-DTPA-mannosyl-dextran (90.1% +/- 10.7% and 97.7% +/- 2.0%, respectively) than for filtered (99m)Tc-sulfur colloid (78.8 +/- 6.5 and 67.4% +/- 26.8%, respectively). (99m)Tc-DTPA-mannosyl-dextran exhibited significantly faster injection site clearance than did filtered (99m)Tc-sulfur colloid. The (99m)Tc-DTPA-mannosyl-dextran percentage injected dose (%ID) for the front and rear paws was 52.6 +/- 10.5 and 52.3 +/- 8.0 at 1 h and 45.7 +/- 8.5 and 43.6 +/- 8.2 at 3 h after administration. The filtered (99m)Tc-sulfur colloid %ID for the front and rear paws was 70.4 +/- 11.0 and 66.3 +/- 15.1 at 1 h and 55.5 +/- 7.8 and 66.9 +/- 8.5 at 3 h. Lymph node accumulation of each agent at either 1 or 3 h was not significantly different. CONCLUSION (99m)Tc-DTPA-mannosyl-dextran is a receptor-based sentinel node radiotracer that exhibits the desired properties of rapid injection site clearance and low distal node accumulation. This molecule is the first member of a new class of diagnostic agents based on a macromolecular backbone with a high density of sites for the attachment of substrates and imaging reporters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sentinel node detection failure due to defective labeling and large particle size of Tc-99m antimony sulfide colloid

  Introduction: Many radiotracers have been used for sentinel node mapping with acceptable results. The main difference between these radiotracers is the particle size. In the current study, we reported defective labeling of Tc-99m antimony sulfide colloid which resulted in large particle size. Methods: Tc-99m-Antimony sulfide colloid was used for axillary sentinel n...

متن کامل

Sentinel node mapping for early breast cancer patients using 99mTc-phytate: Single center experience on 165 patients

Introduction: Several radiotracers are being used for sentinel node mapping in patients with breast cancer. In the current study, we reported our experience with 99m-Tc Phytate for sentinel node mapping in Mashhad University of Medical Sciences. Methods: All breast cancer patients who underwent sentinel node mapping using 99m-Tc Phytate were included. All patients received intradermal peri-are...

متن کامل

Sentinel lymph node biopsy in melanoma patients: An experience with Tc-99m antimony sulfide colloid

  Introduction: Sentinel lymph node biopsy is the standard procedure for lymph node staging in intermediate thickness melanoma. In Iran, this procedure has not been addressed sufficiently. In this study, we report our experience in this area. Methods: Ten consecutive patients with intermediate thickness melanoma where included in our study. 1.5 mCi of Tc-99m antimony...

متن کامل

Time frame of sentinel node visualization in early breast cancer patients using intradermal injection of Tc-99m phytate: Imaging beyond 45 minutes does not yield more information

Introduction: One of the major problems of lymphoscintigraphy is the time of patient presence in the nuclear medicine wards. The operating room schedule can be compromised if the patients stay longer than usual in the nuclear medicine departments. However, too early imaging can be falsely negative for sentinel node visualization and delayed imaging may be required. The aim of t...

متن کامل

The need for skin pen marking for sentinel lymph node biopsy: A comparative study

  Introduction: There is a consensus in the literature that sentinel lymph node biopsy is the standard procedure for axillary staging in early stage (I and II) breast cancer patients. Usually during lymphoscintigraphy, the location of the sentinel lymph node is marked on the skin by an indelible ink. In this study we evaluated this issue in our patients. Methods: 40 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 42 6  شماره 

صفحات  -

تاریخ انتشار 2001