Impaction grafting with a bone-graft substitute in a sheep model of revision hip replacement.

نویسندگان

  • M Coathup
  • N Smith
  • C Kingsley
  • T Buckland
  • R Dattani
  • G P Ascroft
  • G Blunn
چکیده

An experimental sheep model was used for impaction allografting of 12 hemiarthroplasty femoral components placed into two equal-sized groups. In group 1, a 50:50 mixture of ApaPore hydroxyapatite bone-graft substitute and allograft was used. In group 2, ApaPore and allograft were mixed in a 90:10 ratio. Both groups were killed at six months. Ground reaction force results demonstrated no significant differences (p > 0.05) between the two groups at 8, 16 and 24 weeks post-operatively, and all animals remained active. The mean bone turnover rates were significantly greater in group 1, at 0.00206 mm/day, compared to group 2 at 0.0013 mm/day (p < 0.05). The results for the area of new bone formation demonstrated no significant differences (p > 0.05) between the two groups. No significant differences were found between the two groups in thickness of the cement mantle (p > 0.05) and percentage ApaPore-bone contact (p > 0.05). The results of this animal study demonstrated that a mixture of ApaPore allograft in a 90:10 ratio was comparable to using a 50:50 mixture.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subsidence of the stem after impaction bone grafting for revision hip replacement using irradiated bone.

Loss of bone stock is a major problem in revision surgery of the hip. Impaction bone grafting of the femur is frequently used when dealing with deficient bone stock. In this retrospective study a consecutive series of 68 patients (69 hips) who had revision of a hip replacement with femoral impaction grafting were reviewed. Irradiated bone allograft was used in all hips. Radiological measurement...

متن کامل

Impaction bone-grafting in revision joint replacement surgery.

The standard graft material for impaction bone-grafting is fresh-frozen femoral head allograft morselized to a particle size as large as is practical to ensure stability and allow new bone formation. The graft must be sufficiently compacted to provide immediate mechanical stability; this requires containment of the graft and substantial impaction energy. Diaphyseal bone fracture and excessive i...

متن کامل

Impaction bone grafting of the acetabulum at hip revision using a mix of bone chips and a biphasic porous ceramic bone graft substitute

BACKGROUND AND PURPOSE One of the greatest problems of revision hip arthroplasty is dealing with lost bone stock. Good results have been obtained with impaction grafting of allograft bone. However, there have been problems of infection, reproducibility, antigenicity, stability, availability of bone, and cost. Thus, alternatives to allograft have been sought. BoneSave is a biphasic porous cerami...

متن کامل

Acetabular impaction bone grafting in total hip replacement.

The increasing need for total hip replacement (THR) in an ageing population will inevitably generate a larger number of revision procedures. The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. The failed acetabular component requires reconstruction to restore the hip centre and improve joint biomechanics. Impaction bone ...

متن کامل

In-vitro Prediction of Cemented and Non-cemented Revision Stem Stability in Impaction Bone Grafting

BONE GRAFTING +*Mak, S Y; *Smith, S D; *Miles, A W +*Centre for Orthopaedic Biomechanics, University of Bath, UK [email protected] INTRODUCTION: Impaction bone grafting (IBG) has been used in revision hip replacement for more than 15 years. The objective is to impact allograft bone chips into the medullary canal to compensate for bone stock loss after failed primary hip replacement. Initial st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 90 2  شماره 

صفحات  -

تاریخ انتشار 2008