Application of the thermoluminescent technique for calibration and dosimetry of 90 Sr + 90 Y applicators

نویسندگان

  • Patrícia L. Antonio
  • Mércia L. Oliveira
  • Linda V. E. Caldas
چکیده

Dermatological and ophthalmic applicators are used in brachytherapy for the treatment of superficial lesions of skin and eyes. The calibration of these applicators should be realized periodically, according to quality control programs and international recommendations about dosimetry and calibration of brachytherapy sources. Thin thermoluminescent dosimeters of CaSO4:Dy were utilized in this work for the calibration of different applicators using a dermatological applicator as reference. The absorbed dose rates obtained were compared with those of their calibration certificates. Depth dose curves were obtained for all applicators using absorbers of different thicknesses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Dose Calculation of 90 Sr/ 90 Y Source in Water Phantom

Introduction:  90 Sr/ 90 Y source  has  been  used  for  the  intravascular  brachytherapy  to  prevent  coronary  restenosis in the patients who have undergone angioplasty. The aim of this research is to determine the  dose distribution of  90 Sr/ 90 Y source in a water phantom.  Materials  and  Methods:  In  the  present  work,  MCNP  code  has  been  applied  to  calculate  the  dose  distri...

متن کامل

Dosimetric characterization of a high dose rate 192I source for brachytherapy application using Monte Carlo simulation and benchmarking with thermoluminescent dosimetry

Background: The purpose of this project was to derive the brachytherapy dosimetric functions described by American Association of Physicists in Medicine (AAPM) TG-43 U1 based on high dose rate 192I sources. Materials and Methods: The method utilized included both simulation of the designed Polymethyl methacrylate (PMMA) phantom using the Monte Carlo of MCNP4C and benchmarking of the simulation ...

متن کامل

Evaluation of Dose Calculation Accuracy of Isogray Treatment Planning System in Craniospinal Radiotherapy

Introduction: Craniospinal radiotherapy is a therapeutic technique for central nervous system (CNS) tumors, which requires meticulous attention to technique and dosimetry.Treatment planning system (TPS) is one of the main equipment in radiotherapy; therefore, the evaluation of its accuracy is essential for dose calculation. The present study evaluates the validity of Isogray TPS in craniospinal...

متن کامل

The use of gel dosimetry to measure the 3D dose distribution of a 90Sr/90Y intravascular brachytherapy seed.

Absorbed dose distributions in 3D imparted by a single (90)Sr/(90)Y beta particle seed source of the type used for intravascular brachytherapy were investigated. A polymer gel dosimetry medium was used as a dosemeter and phantom, while a special high-resolution laser CT scanner with a spatial resolution of 100 microm in all dimensions was used to quantify the data. We have measured the radial d...

متن کامل

Evaluation of Interferences on Measurements of 90 Sr / 90 Y by the TDCR Čerenkov Counting Technique

Over the last few decades many techniques have been developed for determination of Sr/Y in the environment. Čerenkov counting technique (developed in the 1960s) is widely used, but can be further developed by the application of emerging technologies. For example, it is believed that the application of the triple-to-double coincidence ratio (TDCR) liquid scintillation counting method can be used...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010