Clinical assessment of a plastic optical fiber stylet for human tracheal intubation.

نویسندگان

  • D Gravenstein
  • R J Melker
  • S Lampotang
چکیده

BACKGROUND The authors compared the performance of a prototype intubation aid that incorporated plastic illumination and image guides into a stylet with fiberoptic bronchoscopy and direct laryngoscopy for tracheal intubation by novice users. METHODS In a randomized, nonblinded design, patients were assigned to direct laryngoscopy, fiberoptic bronchoscopy, or imaging stylet intubation groups. The quality of laryngeal view and ease with which it was attained for each intubation was graded by the laryngoscopist. Time to intubation was measured in 1-min increments. A sore-throat severity grade was obtained after operation. RESULTS There were no differences in demographic, physical examination, or surgical course characteristics among the groups. The laryngoscope produced an adequate laryngeal view more easily than did the imaging stylet or bronchoscope (P = 0.001) but caused the highest incidence of postoperative sore throat (P<0.05). Although the time to intubation for direct laryngoscopy was shorter than for imaging stylet, which was shorter than fiberoptic bronchoscopy (P<0.05), the quality of laryngeal view with the imaging stylet was inferior to both direct laryngoscopy and fiberoptic bronchoscopy techniques (P<0.05). CONCLUSIONS Novices using the imaging stylet produce fewer cases of sore throat (compared with direct laryngoscopy) and can intubate faster than when using a bronchoscope in anesthetized adult patients. The imaging stylet may be a useful aid for tracheal intubation, especially for those unable to maintain skills with a bronchoscope.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of a new video-optical intubation stylet versus the conventional malleable stylet in simulated difficult tracheal intubation.

Handling and efficacy of a new video-optical intubation stylet were assessed in a simulated difficult tracheal intubation setting and compared with a conventional malleable stylet. Forty-five anaesthetists performed 10 tracheal intubations using both techniques. Laryngoscopy was performed by the observer, who created a grade 3 view according the classification by Cormack and Lehane. The time ta...

متن کامل

Case report Management of the difficult pediatric airway with Shikani Optical Stylet

Introduction The Shikani Optical Stylet (SOS; Clarus Medical, Minneapolis MN, USA) is another tool to facilitate tracheal intubation. It combines the benefits of a lightwand and a fiberoptic bronchoscope (FOB). It consists of a malleable stainless steel fiberoptic stylet in a preformed ‘J’, a removable ‘no focus’ eyepiece, and either a portable battery-operated light source handle or a traditio...

متن کامل

Video-intuboscopy: a new aid to routine and difficult tracheal intubation.

Video-intuboscopy gives a video display of the view from the tip of the tracheal tube during conventional laryngoscopy, and was developed particularly to assist the immediate management of unexpected difficult intubation. A lightweight, malleable video-optical intubation stylet transmits the view from the stylet tip onto a monitor. It is inserted in the tracheal tube before starting anaesthesia...

متن کامل

New options for airway management: intubating fibreoptic stylets.

Fibreoptic and video technologies are widely used for airway management. Fibreoptics have been used in most airway intubation devices, including rigid laryngoscopes and in the tracheal tube wall itself. 22 Optical stylets, which incorporate ̄exible ®breoptic imaging elements in an intubation stylet, have now also become available. More than 10 new optical stylet devices have been introduced sinc...

متن کامل

A rare cause of endotracheal tube obstruction: a broken stylet going unnoticed--a case report.

In anesthesia practice, stylet is used as an aid in difficult tracheal (ET) intubation. Disposable plastic covered or plastic bougies are recommended but in developing countries, the metal stylets are still in use. Shearing of part of stylet has been reported in past but all incidents were detected immediately. We report a case of tracheal tube blockade due to a broken stylet tip which initiall...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 91 3  شماره 

صفحات  -

تاریخ انتشار 1999