A computational study of knitted Nitinol meshes for their prospective use as external vein reinforcement.

نویسندگان

  • Helena van der Merwe
  • B Daya Reddy
  • Peter Zilla
  • Deon Bezuidenhout
  • Thomas Franz
چکیده

External reinforcement has been suggested for autologous vein grafts to address the mismatch of mechanical properties and fluid dynamics of graft and host vessel, a main factor for graft failure. A finite-element tool was developed to investigate the mechanical behaviour, in particular radial compliance, of knitted Nitinol meshes (internal diameter: 3.34 mm) with two different knit designs (even versus uneven circumferential loops) and three different wire thicknesses (0.05, 0.0635 and 0.075 mm) under physiological conditions. The Nitinol material parameters were obtained from experimental testing. The compliance predicted for the 80-120 mmHg physiological blood pressure range was 2.5, 0.9 and 0.6%/100 mmHg for the even loop design and 1.2, 0.5 and 0.5%/100 mmHg for the uneven loop design, for wire thicknesses of 0.05, 0.0635 and 0.075 mm. The highest stress, at 120 mmHg, was found in the even loop mesh with the thinnest wire to be 268 MPa, remaining 44.5% below the stress initiating stress-induced phase transformation. The maximum stress decreased to 132 and 91 MPa with increasing wire thickness of the same loop design. The uneven loop design exhibited maximum stress levels of 65.3%, 63.6% and 87.9% of the even loop values at 0.05, 0.0635 and 0.075 mm wire thickness. The maximum strain of 0.7%, at 120 mmHg, remained un-critical considering a typical high-cycle recoverable strain of 2%. It was demonstrated that the numerical approach developed was feasible of effectively evaluating design variations of knitted Nitinol meshes towards vein graft behaviour equivalent to arterial mechanics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Knitted nitinol represents a new generation of constrictive external vein graft meshes.

OBJECTIVE Constriction of vein grafts with braided external nitinol meshes had previously led to the successful elimination of neointimal tissue formation. We investigated whether pulse compliance, smaller kink-free bending radius, and milder medial atrophy can be achieved by knitting the meshes rather than braiding, without losing the suppressive effect on intimal hyperplasia. METHODS Pulse ...

متن کامل

Tailored sizes of constrictive external vein meshes for coronary artery bypass surgery.

External mesh constriction of vein grafts was shown to mitigate intimal hyperplasia by lowering circumferential wall stress and increasing fluid shear stress. As under-constriction leaves vein segments unsupported and thus prone to neointimal proliferation while over-constriction may cause wall folding optimal mesh sizing holds a key to clinical success. Diameter fluctuations and the occurrence...

متن کامل

Computerized tomographic angiography in patients having eSVS Mesh® supported coronary saphenous vein grafts: intermediate term results

BACKGROUND The Saphenous Vein (SVG) is used in over 80% of coronary artery bypass procedures (CABG) and SVG patency is the Achilles heel of CABG. To address this issue, the eSVS Mesh(R), an external Nitinol knitted mesh, fitted like a sleeve over the vein graft preventing over expansion in the high pressure arterial system, has been introduced to improve disease management. Patency data is limi...

متن کامل

Nitinol Spinal Vertebrae: A Favorable New Substitute

Scoliosis, kyphosis, and bone fracture are health problems, especially of the elderly throughout the world. The vertebra protects the spinal cord. Any impairment to the vertebra can lead to pain and nervousness. Ni-Ti alloy (Nitinol) helps to resolve the problem by fulfilling such requirements as for strength, durability, resistance to wear, and shockwave damping which is due to the shape memor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 41 6  شماره 

صفحات  -

تاریخ انتشار 2008