PURPOSE Proton beam therapy is a commonly accepted treatment for intraocular melanomas, but the literature is lacking in descriptions of patient preferences of clinical outcomes and economic impact. In addition, no economic evaluations have been published regarding the incremental cost-effectiveness of proton beam therapy compared with enucleation or plaque brachytherapy, typical alternative treatments. We, therefore, conducted a cost-utility analysis of these three approaches for the treatment of intraocular melanomas. MATERIALS AND METHODS A Markov model was constructed. Model parameters were identified from the published literature and publicly available data sources. Cost-effectiveness of each treatment was calculated in 2011 US Dollars per quality-adjusted life-year. Incremental cost-effectiveness ratios were calculated assuming enucleation as reference. One-way sensitivity analyses were conducted on all model parameters. A decision threshold of $50,000/quality-adjusted life-year was used to determine cost-effectiveness. RESULTS Enucleation had the lowest costs and quality-adjusted life-years, and plaque brachytherapy had the highest costs and quality-adjusted life-years. Compared with enucleation, the base-case incremental cost-effectiveness ratios for plaque brachytherapy and proton beam therapy were $77,500/quality-adjusted life-year and $106,100/quality-adjusted life-year, respectively. Results were highly sensitive to multiple parameters. All three treatments were considered optimal, and even dominant, depending on the values used for sensitive parameters. CONCLUSION Base-case analysis results suggest enucleation to be optimal. However, the optimal choice was not robust to sensitivity analyses and, depending on the assumption, both plaque brachytherapy and proton beam therapy could be considered cost-effective. Future clinical studies should focus on generating further evidence with the greatest parameter uncertainty to inform future cost-effectiveness analyses.
منابع مشابه
Effects of Defining Realistic Compositions of the Ocular Melanoma on Proton Therapy
Background: Recent studies in eye plaque brachytherapy have shown a considerable difference between the dosimetric results using water phantom and a model of human eye containing realistic materials. In spite of this fact, there is a lack of simulation studies based on such a model in proton therapy literatures. In the presented work, the effect of utilizing an eye model with ocular media on pr...
متن کاملA new model for Spread Out Bragg Peak in proton therapy of uveal melanoma
In this research, in order to improve our calculations in treatment planning for proton radiotherapy of ocular melanoma, we improved our human eye phantom planning system in GEANT4 toolkit. Different analytical models have investigated the creating of Spread Out Bragg Peak (SOBP) in the tumor area. Bortfeld’s model is one of the most important analytical methods. Using convolution method, a new...
متن کاملComplications from Plaque versus Proton Beam Therapy for Choroidal Melanoma: A Qualitative Systematic Review
Plaque brachytherapy has been a mainstay of treatment for choroidal melanoma to achieve intraocular tumor control. The most common radioisotopes used for treating smaller sized tumors are Iodine-125 in North America and Ruthenium-106 in Europe. Proton beam radiotherapy is available at a few centers and may also be used to achieve local tumor control. Both plaque and proton beam therapy are know...
متن کاملDose Assessment of Eye and Its Components in Proton Therapy by Monte Carlo Method
Introduction Proton therapy is used to treat malignant tumors such as melanoma inside the eye. Proton particles are adjusted according to various parameters such as tumor size and position and patient’s distance from the proton source. The purpose of this study was to assess absorbed doses in eyes and various tumors found in the area of sclera and choroid and the adjacent tissues in radiotherap...
متن کاملIntraocular inflammation after proton beam irradiation for uveal melanoma.
AIM To describe the inflammatory reaction that can occur following proton beam irradiation of uveal melanomas based on a large series of patients and to try to determine the risk factors for this reaction. METHODS Data from a cohort of patients with uveal melanoma treated by proton beam irradiation between 1991 and 1994 were analysed. The presence of inflammation was recorded and evaluated. K...