Intercomparison of retrospective radon detectors.

نویسندگان

  • R W Field
  • D J Steck
  • M A Parkhurst
  • J A Mahaffey
  • M C Alavanja
چکیده

We performed both a laboratory and a field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, (210)Pb, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha-emission of a (210)Pb-decay product, (210)Po. The detector's track density generation rate (tracks per square centimeter per hour) is proportional to the surface alpha-activity. In the absence of other strong sources of alpha-emission in the glass, the implanted surface alpha-activity should be proportional to the accumulated (210)Po, and hence to the cumulative radon gas exposure. The goals of the intercomparison were to a) perform collocated measurements using two different glass-based retrospective radon detectors in a controlled laboratory environment to compare their relative response to implanted polonium in the absence of environmental variation, b) perform collocated measurements using two different retrospective radon progeny detectors in a variety of residential settings to compare their detection of glass-implanted polonium activities, and c) examine the correlation between track density rates and contemporary radon gas concentrations. The laboratory results suggested that the materials and methods used by the studies produced similar track densities in detectors exposed to the same implanted (210)Po activity. The field phase of the intercomparison found excellent agreement between the track density rates for the two types of retrospective detectors. The correlation between the track density rates and direct contemporary radon concentration measurements was relatively high, considering that no adjustments were performed to account for either the residential depositional environment or glass surface type. Preliminary comparisons of the models used to translate track rate densities to average long-term radon concentrations differ between the two studies. Further calibration of the retrospective detectors' models for interpretation of track rate density may allow the pooling of studies that use glass-based retrospective radon detectors to determine historic residential radon exposures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

International Intercomparison Exercise on Natural Radiation Measurements under Field Conditions (ifc11)

One of the aims of the First Intercomparison on Natural Radioactivity Under Field Conditions was to test different instruments and detectors for the measurement of radon gas and external gamma radiation (dose rate) in filed conditions, where the levels of natural radiation are quite high. The event was organized by the Radon group of University of Cantabria, (Spain) LaRUC, and was held in the e...

متن کامل

Measurement of Contemporary and Retrospective Radon Concentration in Ramsar Dwellings Using Polycarbonate Detector

The origins of radon gas are the amount of uranium decay in the soil that is released into space and through the interior gaps of  buildings. Radon can enter the respiratory system and cause radiation hazards. Recently research has identified Radon as the second leading cause of lung cancer after cigarette smoking. The indoor concentration of Radon progeny is mentioned as an important issue reg...

متن کامل

Influence of environmental changes on integrating radon detectors: results of an intercomparison exercise.

An intercomparison exercise for passive integrating radon detectors has been carried out with the participation of 12 detection systems from 10 laboratories. The detection systems comprise three commonly used in radon integrating measurements, tracks, activated charcoal canisters and electrets. The exposures were carried out in the radon and thoron chambers at the Institute of Energy Techniques...

متن کامل

Intercomparison of radon CR-39 detector systems conducted in CLOR’s calibration chamber

Within the framework of the grant of the Polish Ministry of Science and Higher Education entitled Seasonal changes of indoor radon (222Rn) concentrations of Poland (N506 1127 33) radon laboratories united in the Radon Center – the Non-governmental International Scientific Network – perform measurements of radon concentration in houses located in various areas of Poland. These laboratories belon...

متن کامل

Retrospective assessment of historic radon concentrations in Norwegian dwellings by measuring glass implanted Po-210--an international field intercomparison.

The first Norwegian study of historic radon concentrations in 17 dwellings in the high radon areas in Norway has been conducted as part of an international field intercomparison during 1998. The retrospective radon concentration is estimated via measurements of Po-210, the long-lived decay product of Rn-222 implanted in glass surfaces of objects like pictures, mirrors, cabinet-glass, etc. the m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 107  شماره 

صفحات  -

تاریخ انتشار 1999